Form documenting building details and inspection results for 300 Albany Street, including checks for ACM, air monitoring, and facade conditions.

NYC-WTC_000116234–000116267

Folder label: “320 ALBANY STREET 000301, 16/7502

Page image
Scanned page image, NYC-WTC_000116264
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document L.1 Lentral Ventilation System Visual Inspection Form I ♦t♦ C..♦ is c Page 1 of 2

Area iv Uo H *1J)QK — .t; Associated mechanical room: clean Y N Y N stored chemicals/refuse Y N System Components Surface Component {NOTE: if component notpresent (NP), not found (PM or Dust/ WTC • not present inaccessible (1) please Debris Dust •not found indicate in last column] Present? Present? • Outside air intntcer T ....s.:..... Inaccessible

Accessible for inspection? Y „i/1 ,N (explain):

— louvers, grates and/or screens — outside air duct — outside air damper(s)

— outside air mixing chamber — filter rack(s) — filter media — blower assembly incl. blower wheel, blower housing, air vanes, in-line noise attenuators — blower housing acoustical lining — pre-heat coils — heating coils — cooling coils — re-heat coils — condensate drain pan — supply air plenum — supply air plenum damper(s) — vibration collars Supply air distribution: — Supply air ducts Est. total In ft %6t No. locations inspected_ 2 Specify type (circle): sous glasi me m ox fibrous glass board • -dc _wc .: — Accessible in-line fire dampers Est total qty No. locations inspected — Accessible turning vanes Est. total qty_3 No. locations inspected-- _ — In-line reheat/cooling coils Est. total qty No. locations inspected — Supply air diffusers Est total qty No. locations inspected 1 Return air distribution: — Return air ducts Est. total In ft No. locations inspected Specify type (circle): eta fibrous glass lined metal masonry fibrous glass board flex-du ww o — Return air plenum Est. total RA plenum areas N No. locations inspected — Return air plenum damper Est, total qty No. locations inspected — Accessible in-line fire dampers Est. total qty No. locations inspected — Accessible turning vanes Est. total qty No. locations inspected — Return air grilles Est, total qty No. locations inspected

NYC-WTC-000116264

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000116264Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →