WTC building inspection form, 320 Albany Street

Machine-extracted title · confidence 90%

Form documenting visual facade inspections and air monitoring status for a building at 320 Albany Street.

NYC-WTC_000116169–000116225

Folder label: “320 ALBANY STREET 000301, 16/7502

Page image
Scanned page image, NYC-WTC_000116202
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

2.1 Central Ventilation System Visual Inspection Form pnoe I of I Ventilation System Identification:

Location: 00 A LS AP ST R.EeT Area Served: t%JOr'-t t9€ a1 Lo 13`t 1srMicE L8%1 Associated mechanical room: clean Y N dry Y N stored chemicals/refuse Y N Surface Component System Components Dust! WTC • not present [NOTE: if component not present (NP), not found (NF) or inaccessible (1) please Debris Dust • not found indicate in last colunini Present? Present? • inaccessible Outside air intake: Location:

Accessible for inspection? Y N (explain):

— louvers, grates and/or screens — outside air duct — outside air damper(s) Air handling unit: — outside air mixing chamber N? — filter rack(s) — filter media '/ iU — blower assembly incl. blower wheel, blower housing, air vanes, in-line noise attenuators Al — blower housing acoustical lining — pre-heat coils — heating coils — cooling coils — re-heat coils 1 — condensate drain pan , — supply air plenum — supply air plenum damper(s) — vibration collars Supply air distribution: — Supply air ducts Est. total in 2 No. locations inspected Specify type (circle): etgJ fibrous glass lined etas masonrs~ fibrous glass board flex -duct wo — Accessible in-line fire dampers Est. total qty No. locations inspected p — Accessible turning vanes Est. total qty No. locations inspected N — In-line reheat/cooling coils Est. total qty No. locations inspected N — Supply air diffusers Est. total qty _ No. locations inspected Return air distribution: — Return air ducts Est. total In ft No. locations inspected I Specify type (circle):( iibrpps glass lined metal ammasomv fibrous glass board flex-duct w od — Return air plenum Est. total RA plenum areas t No. locations inspected_, — Return air plenum damper Est. total qty No. locations inspected — Accessible in-line fire dampers Est total qty No. locations inspected — Accessible turning vanes Est total qty No. locations inspected — Return air grilles Est. total qty I No. locations inspected

NYC-WTC 000116202

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000116202Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →