HVAC inspection invoice, 380 Rector Place, Jan 2003

Machine-extracted title · confidence 100%

Invoice from Athenica Environmental Services for HVAC and environmental inspections performed at 380 Rector Place on January 13, 2003.

NYC-WTC_000113892–000113951

Folder label: “380 RECTOR PL 1000544, 16/7505

Page image
Scanned page image, NYC-WTC_000113928
OCR text

OCR status: ocr · source: ours

NYC 9/11 Public Portal Document 2.2 Mechanical Exhaust System Visual Inspection Form Mechanical Exhaust System Identification: EXHAUST #3 Location: 250 SOUTHEND AVE/ MAIN ROCF Area Served: Associated mechanical room: clean y Y_N dry_ Nstored chemicals/refuse_ System Components INOTE: if component not present (NP), not found (NF) or inaccessible (I) please indicate in last column] Exhaust air outlet: Location: Y Accessible for inspection? Y N _(explain): - louvers, grates and/or screens - outside air duct - outside air damper(s) Exhaust fan unit: - blower assembly incl. blower wheel, housing, air vanes, in-line noise attenuators - blower housing acoustical lining - vibration collars Exhaust air distribution: - Exhaust air ducts Est. total In ft 180 No. locations inspected| Specify type (circle): (metal (fibrous glass lined metal masonry fibrous glass board flex-duct wood - Accessible in-line fire dampers Est. total qty_ - Accessible turning vanes Est. total gty - Exhaust air grilles Est. total qty 19 No. locations inspected No. locations inspected No. locations inspected_0 Otber (specify): Other Information: Surface Dust/ DebrisR Present? Y Y Page 1 of 1 N WTC Dust Present? Component •not present • not found • inaccessible Y NP NP NP •• NP NP I General impression (indicate recommendations for cleaning based on finding of WTC dust): -THE BLADES OF EXHAUST FAN ARE COVERED WITH WTc related dust. -THE FIBERELASS LINING 1S COVERED WOTH LIiN COATING OF WTC dust. - CLEANING IS REQUIRED IOR WTC RELATED DUST. - CLEAN THE EXHAUST FAN UNIT ALONG WITH ITS COMPONENTS AND ITS ASSOCIATED DUCT. KEY: NP = not present; NF = not found; I= inaccessible; U = unknown NYC-WTC_000113928

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000113928Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →