NYC 9/11 Public Portal Document
ATC Associates
104 East 25 Street, New York, NY 10010
Phone: (212) 353.8280 Fax: (212) 353-8306 ATC
Attn: Mr. Fabio Pedone
Received: 6/26/02 6:00:00 AM
Widen & Panzer Engines s . P.C. ATC Group #; 8302
228 E. 45th Street
Analysis Date: 6/27/02
New York NY 10017
Fax: (212) 922.0630 Phone: (212) 922-0077
Project: NYC-DEP W & P File #: 1079.01.02
Asbestos Fiber Analysis by Transmission Electron Microscopy
(TEM) performed
by EPA 40 CFR Part 763 Final Rule (AHERA)
Analytical drbesles
Area Non Adbe$tat # Srruetwes Sbesitsvjy Ceneeebation
Sample Valxnte Analyzed dab 7yp (s) •aspti5 sp (S/cc) (S/tnnt) (S/cc) Notes
01 1512.00 0,0562 0 CNRYSOTILE 0 1 0,0045 ' 5 ' 0.0045
8102 -1
ACTINOUTE I
02 15I2.00 0.0562 0 None 0etecred 0 0 0.0045 c 17.79 <0.0045
8102 -1
01 1314.00 0.0674 0 None 0e:ecled 0 0 0.0043 < 14.83 <0.0043
8302 -3
04 1314.00 00674 0 None 0o',e ed 0 0 0.0043 < 14.83 <0.0043
0` 512.00 0.0562 0 Nero Detoawd 0 0
5302 -1 0.0045 <17.79 <0.0045
MARK PEYSAKHOV MICHAEL A. GORYCKI, Ph.D.
Analyzed bY .....~ .-^---- — —•
Approved by:
Oisdaimer; The laboratory is not rosponaibie for daQt ICparhed in 3tftactuns1Z whirl is
dependent On vdume oaleCted by roe-laboratsiry oees:r eL This lab Is only responsible
rat reported In strucWres(rrrn'. This report may not be repro iureC. except In full wPJaolt write approval by ATC Assodatrs in This report may not be used to dalm
prod YCf vhdorsarnenl by NVLAP or any odw open,/ of the U.S. Govanrhaht This reop
rgiatts only to the samples reported above. Quality control data (Indudtng 9S'%
confdence P.mlts and laboratory and anaiysls' 2cjracy i , Ø prealsan) b available upon netrest
Accredited for NVLAP =LMREM #101187.0, NY Slate El AP #10879
PageIof)
NYC-WTC 000112287