NOV. 20. 2001 3:27PM FF CATASTROPHE NO. 652 P. 6

8. 40 CFR Part 260 - Hazardous Waste Management System: General

9. 40 CFR Part 261 - Identification and Listing of Hazardous Waste

10. 40 CFR Part 262 - Standards Applicable to Generators of Hazardous Waste

11. 40 CFR Part 263 - Standards Applicable to Transporters of Hazardous Waste

12. 40 CFR Part 264 - Standards Applicable to Owners and Operators of Hazardous Waste Treatment, Storage, and Disposal Facilities

13. 40 CFR Part 265 - Interim Status Standards for Owners and Operators of Hazardous Waste Treatment, Storage, and Disposal Facilities

14. 40 CFR Part 50 - "National Ambient Air Quality Standards for Lead"

The above listing is not intended to be exhaustive. The contractor is responsible for compliance with all applicable laws, rules and regulations whether or not they have been listed above.

1.5 Fire Protection

A. The Contractor shall provide a fire watch (i.e. guard service) in compliance with NFPA 601/602. The watch shall be provided from the onset of asbestos removal until the contractor has completed their scope of work and has removed all equipment/materials from the site. The personnel providing said fire watch will not be allowed in the containment work area. The owner will provide fire protection services including fire hose and water.

B. Contractor must supply the work area with adequate quantity of charged and inspected fire extinguishers at designated locations within and outside the work area, and familiarize employees regarding the location and operation of the extinguishers in compliance with OSHA regulations (1926.150) and National Fire Protection Association (NFPA) guidelines (10A-1998). OSHA requires at least one, 2A or greater extinguisher for each 3,000 square feet of work area.

C. Extinguishers must have a record of inspection and service within the past 12 months.

1.6 Air Monitoring

A. Air Monitoring (Except for the Contractor's OSHA compliance monitoring) will be performed by the Environmental Consultant.

B. The Environmental Consultant will collect air samples in accordance with the New York State Department of Labor Industrial Code Rule 56 requirements. Samples will be analyzed by Phase Contrast Microscopy by a New York State Department of Health Certified Laboratory.

4

NYC-WTC 000112122

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000112122Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →