NYC Law Department release
Independent mirror · updated as the City releases more · v1.3.2
☕ Buy me a coffee
← Document results/Asbestos - BOX 6/250 BROADWAY; Block: 124 Lot: 24 BIN: 1001408 245 Broadway, 2-4 Murray St. 1-7 Park Pl, 239- 247 Broadway
Document / 12 pages

250 BROADWAY; Block: 124 Lot: 24 BIN: 1001408 245 Broadway, 2-4 Murray St. 1-7 Park Pl, 239- 247 Broadway

Label derived from the City's folder field. The City does not supply document titles.NYC-WTC_000105994–000106005
Page image
Scanned page image, NYC-WTC_000106000
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

10/01/2001 11:26 2125984283 ATC ASSOCIATES PAGE 02/0: ATC ASSOCIATES,INC 104 E 25th Street,10th Floor New York,NY 10010 Tel. 212-353-8280 Fax 212-353-8306

09-19-JK-13 14109 8N Post Coil Room Floor 12x12 24.2 9.0 P 09-19-JK-14 14I09 SN Coil Room Floor 12x12 29.2 9.0 p 09-19-JK-15 14109 8N Right Mixing Chamber Floor 12x12 <9.0 9.0 p 09-19-JK-16 14109 8N Drip Pan Room Floor 12x12 832.3 9.0 F 09-19-JK-17 14I09 8N Coil Room Floor 12x12 <9.0 9.0 p 09-19-JK-18 14109 8N Filter Room Floor 12x12 22.4 9.0 P 09-19-JIC-19 14109 8N Mixing Chamber Floor 12x12 13.7 9.0 P 09-19-JK-20 14109 8S Post Coil/Drip Pan Room Floor 12x12 723.2 9.0 F 09-19-JK-21 14109 8S Filter Room Floor 12x12 2I9.3 9.0 F 09-19-JIC-22 14109 8S Pre Coil/Filter Room Floor 12x12 18.1 9.0 P 09-19-IK-23 14109 31 Left Mixing Chamber Floor 12x12 13.1 9.0 P 09-19-JK-24 14109 31 Left Coil Room Floor 12x12 <9.0 9.0 P 09-19-JK-25 14109 31 Left Precoil Room Floor 12x12 10.0 9.0 P 09-19-JK-26 14109 31 Center Mixing Chamber Floor 12x12 <9.0 9.0 P 09-19-JIC-27 I4.109 31 Filter Room Center Floor 12x12 <9.0 9.0 P 09-19-JK-28 14109 31 Center Coil Room Floor 12x12 <9.0 9.0 P 09-19-JK-29 14109 31 Center Pre-Coil Room Floor 12x12 34.3 9.0 P 09-19-JK-30 14109 19N Coil Room Floor 12x12 <9.0 9.0 P 09-19-JK-31 14109 l9N Pre Coil/Drip Pan Floor 12x12 <9.0 9.0 P 09-19-JK-32 14109 19N Mixing Chamber Floor 12x12 <9.0 9.0 F 09-19-JK-33 14109 19S Mixing Chamber Left Floor 12x12 <9.0 9.0 F 09-19-JK34 14109 19S Filter Room Floor .12x12 <9.0 9.0 F 09-19-J1:-35 14109 19S Post Coil Room Floor 12x12 <9.0 9.0 1 09-19-J1C-36 14109 19S Coil Room Floor 12x12 <9.0 9.0 1 09-19-JK-37 14109 19S Fan Unit Room Floor 12x12 <9.0 9.0 1

NOTE 1: TILE REPORTING LIMIT (12L) IS 18.0 µg NOTE 2: HUD Guidelines for final clearance dust wipe samples: Floor 40 µye/ft, Window sills 25t Window wells 400 µget; , 6xtcrior surfaces 800 µg/11=.

page 2 of 3

NYC-WTC 000106000

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000106000Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →