OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document - PAGE 02/03 10/01/2001 11:26 2125984283 ATC ASSOCIATES

ATC •ASSOCUTES, INC 104 E 25th Street, 10th Floor New York, NY 10010 Tel. 212-353-8280 Fax 212-353-8306

09-19.JK-13 14109 8N Post Coil Room Floor 12x12 24.2 9.0 P 09-19-JK-14 14I09 SN Coil Room Floor 12x12 29.2 9.0 p

09-19-JK-I5 14109 8N Right Mixing Chamber Floor 12x12 <9.0 9.0 P

09-19-JIC-16 14109 8N Drip Pan Room Floor 12x12 832.3 9.0 F

09-19-JK-17 14109 8N Coil Room Floor 12x12 <9.0 9.0 P

09-19-JK-18 14109 8N Filter Room Floor 12x12 22.4 9.0 P

09-19-JIC-19 14109 8N Mixing Chamber Floor 12x12 13.7 9.0 ' P

09-19-JK-20 14109 8S Post Coil/Drip Pan Room Floor 12x12 723.2 9.0 F

09-19-JK-21 14109 SS Filter Room Floor 12x12 219.3 9.0 F

09-19-JIC22 14109 8S Pre Coil/Filter Room Floor 12x12 18.1 9.0 P

09-19-JK23 14109 31 Left Mixing Chamber Floor 12x12 13.1 9.0 P

09-19-JK-24 14109 31 Left Coil Room Floor 12x12 <9.0 9.0 P

09-19-JK-25 14109 31 Left Precoil Room Floor 12x12 10.0 9.0 P

09-19-7K-26 14109 : 31 Center Mixing Chamber Floor 12x12 <9.0 9.0 P

09-19-JIC-27 14109 31 Filter Room Center Floor 12x12 <9.0 9.0 P

09-19-JK-28 14109 31 Center Coil Room Floor 12x12 <9.0 9.0 P

09-19-JK-29 14109 31 Center Pre-Coil Room Floor 12x12 34.3 9.0 P

09.194IC-30 14109 !9N Coil Room Floor 12x 12 <9.0 9.0 P

09-19-JK-31 14109 19N Pre Coil/Drip Pan Floor 12x12 <9.0 9.0 P

09-19-JIC-32 14109 19N Mixing Chamber Floor 12x12 <9.0 9.0 F

09-19-JK-33 14109 19S Mixing chamber Len Hoot ltxia "7.0 ~•~

09-19-JK-34 14109 19S Filter Room Floor 12x12 <9.0 9.0

09-19-JIC-35 14109 19S Post Coil Room Floor 12x12 <9.0 9.0

09-19-JK--36 . 14109 19S Coil Room Floor 12x1.2 <9.0 9.0 }

09-19-SK-37 14109 I9S Fan Unit Room Floor 12x12 <9.0 9.0 •'

NOTE 1: TILE REPORTING LIMIT (EL) IS 18.0 µg NOTE 2: HUD Guidelines for final clearance dust wipe samples Floor 40 }AgHt=, Window sills 250 µIll, Window wells 400 µghV, Exterior surfaces 800 4111d.

page 2 o£ 3

~•-,aa~,a2 Pt~i;C ?7 NYC-WTC 000106068

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000106068Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →