Machine-extracted title · confidence 85%

Letter from Testwell Laboratories dated June 6, 2002, regarding an inspection at 200 Park Avenue.

NYC-WTC_000105886–000105888

Folder label: “209 BROADWAY; 1001231, 87/1

Page image
Scanned page image, NYC-WTC_000105886
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

IL A Minority Business Enterprise

TESTWELLM LABORATORIES,INC. 47 Hudson Street, Ossining, New York 10562 Total Commitment to Quality Tel: (914)-762-9000 • Fax: (914)-762-9638 • testwelllabs.com

Offices in June 6, 2002 Albany, NY Mr. Michael Deane Queens, NY Bovis Lend Lease LMB, Inc. Woodbridge, NJ 200 Park Avenue Miami, FL New York, New York 10166 [email protected] Telephone: (212) 592-6912 Qmrcations & Facsimile: (212) 592-6988 Accreditation Regarding: Fungal Inspection and Prevention 55 Church Street New York, New York

Dear Mr. Deane,

Ell IIS0900I CERTIFIED As requested we have inspected accessible areas of the building for signs of fungal growth and wish to provide you with preliminary findings of our efforts. To date, we have conducted the following activities:

1. Field survey of wall and ceiling surfaces on floors 45-55 to determine moisture readings of walls and reconnaissance for visible fungal growth. NV A 2. Reconnaissance of podium and lower levels for visible fungal growth. Nvuaus CODE 20ooas-0 3. Collection of samples for presence of fungal contamination. 4. Establish preliminary recommended actions to prevent fungal growth.

Field Survey of Floors 45-55 SM Moisture reading taken in each room on floors 45-55 did not indicate moist conditions suitable for fungal growth. Signs of fungal growth were evident, however, in isolated areas. These areas mostly consist of mechanical chases iSl.ffo R18 adjacent to the individual fan coil units in guest and function rooms on the upper floors. A significant number of the drywall chases on the top floors (51-55) showed signs that fungal growth had been present. Lower floors (45-50), however, showed little to no indication of fungal growth. Fungal growth was also M'S DOH ELAP #10871, observed in locations where ice making machines were previously 11142 & 11651 located. There was no standing water observed on any of the floors inspected. Reconnaissance of Podium and Lower Levels A visual inspection of the podium floors and lower levels was conducted. Moisture readings were not conducted, as the areas did not yet have finishes (i.e. vinyl backed wallpaper) stripped.

Visual inspection of the podium floors 3, 4, 5 revealed nosins of fungal ngal growth. D es. The inspection included the casework and walls along the I aacre~rea west facade, where a

CERT. No.10014 m

NYC-WTC 000105886

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000105886Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →