NYC-WTC_000128550
Asbestos inspection report notification form submitted to NYC DEP for 102-104 Greenwich Street.
17 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗Facsimile cover sheet transmitting documents regarding environmental work at 102 Greenwich Street.
NYC-WTC_000104853–000104885Folder label: “102 GREENWICH STREET Block: 53 Lot: 37 BIN:1001054 104 Greenwich Street”

OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
AEi2,L.L.C. ASBESTOS Asbestos Abatement & Environmental Cleanup
FIELD EQUIPMENT Construction/Remediation Equipment * Bobcat 753 Backhoe with Hydraulic * Ford with Guzzler Model XCR 4816TC Hammer & Sweeper Wet/Dry Vacuum Truck & Swing Out * CAT 416 Rubber Tire Backhoe Cyclone for direct loading * CAT 426B Rubber Tire Backhoe * Ford L8000 20CY Dump Truck * Mitsubishi MS180 1.5CY Excavator * 30' Field Office/Decontamination Trailer * Volvo with Guzzler- Model XCR 4816TC * Ford F150 Van Wet/Dry Vacuum Truck & Swing Out * Ford F250 Van Cyclone for direct loading * Ford F350 14' Box Trucks
Asbestos Removal Equipment * Air Flow Testers * Binks Airless Spraying Compressors * Paramount Leaf Blowers * Fog Master Tri-Jet Misting Machines * Geyer Utility Pumps * Homelite Portable AC Power Generators * HEPA Negative Air Filtration Units (micro) * Wicno Portable AC Power Generators * Nilfisk Vacuums * Triden Air Circulation HEPA Units * Hako Minute Man HEPA 15-gallon Vacuums * Insulazer High Pressure Washer * Hako Back Pack Vacuum * Type C Supplied Air System
Miscellaneous Equipment * Scaffolding Frames (complete) * Spin Jet Nozzle * Platforms * Drum Pump * Pressure Washers * 2" Trash Pump * 3" Aluminum Double Diaphragm Pumps * Complete Torch Sets * 2" Aluminum Double Diaphragm Pumps * Nitrogen Tank Inerting System * 3/4" Plastic Double Diaphragm Pumps
Direct Reading Environmental Indicator Personal Protective Equipment * Photoionization Detector * Full Face Air Purifying Respirators • * LEL/02Indicator * Supplied air Respirators * Colormetric Indicator Tubes * Plastic Coated Tyveks * Chemical Resistant Boots & Gloves
43 Jefferson Avenue 856-768-9200 fax: 856-768-5499 Berlin, New Jersey 08009 e-mail: [email protected] (856) 768-9200
NYC-WTC 000104884
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
No available related records indexed in this group.
NYC-WTC_000128550
Asbestos inspection report notification form submitted to NYC DEP for 102-104 Greenwich Street.
17 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗9 shared non-person entities · 1 shared topics · similarity 0.981
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000154680
Application form submitted to the Department of Environmental Protection for notification of an asbestos inspection project.
10 shared non-person entities · 1 shared topics · similarity 0.977
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000112116
NYC DEP emergency notification form documenting an urgent asbestos abatement situation at 250 Vesey Place requiring immediate action.
10 shared non-person entities · similarity 0.971
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000125579
Technical specifications document prepared for asbestos abatement work at the 130 Cedar Street site.
11 shared non-person entities · similarity 0.970
machine-extracted · confidence unavailable · Check page ↗14 shared non-person entities · 1 shared topics · similarity 0.968
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000155525
Initial draft of the comprehensive scope of work required to safely clean 114 Liberty Street following environmental damage.
14 shared non-person entities · 1 shared topics · similarity 0.968
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000135560
Application for permits regarding exterior remediation work at World Trade Center vicinity buildings.
6 shared non-person entities · 1 shared topics · similarity 0.967
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000098577
Contract specifications outlining site decontamination and asbestos disposal procedures for 53 Park Place.
9 shared non-person entities · 1 shared topics · similarity 0.967
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000155460
Submission of a preliminary scope of work document for safely cleaning the 114 Liberty Street building.
13 shared non-person entities · 1 shared topics · similarity 0.966
machine-extracted · confidence unavailable · Check page ↗13 shared non-person entities · 1 shared topics · similarity 0.966
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000107379
Formal request by a resident for the Department of Environmental Protection to perform cleaning and monitoring work at their apartment.
7 shared non-person entities · 1 shared topics · similarity 0.965
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000150079
Guidance issued by DEP to building owners outlining procedures for cleaning dust and debris potentially containing asbestos.
Similarity score 0.935 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000132680
A letter from Capital Properties submitting additional air quality monitoring results for Broadway and Trinity Place buildings to the DEP.
Similarity score 0.933 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000125579
Technical specifications document prepared for asbestos abatement work at the 130 Cedar Street site.
Similarity score 0.933 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000152149
A fax cover sheet from the Department of Environmental Protection dated September 19, 2001.
Similarity score 0.933 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000141838
Formal memorandum from the DEP Commissioner instructing building representatives on safe asbestos handling and sampling protocols following the disaster.
Similarity score 0.932 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000100522
Cover page for an asbestos project notification form submitted to the New York City Department of Environmental Protection.
Similarity score 0.931 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
Review draft of an environmental health and safety plan for debris operations at Staten Island Landfill.
Cited alongside this record in an Ask answer
NYC-WTC_000128550
Asbestos inspection report notification form submitted to NYC DEP for 102-104 Greenwich Street.
Cited alongside this record in an Ask answer
NYC-WTC_000150256
Table of contents for a site control plan document regarding landfill entry and exclusion zones for WTC debris.
Cited alongside this record in an Ask answer
NYC-WTC_000148621
Memo outlining DEP activities including assessment and coordination with federal agencies for street and sidewalk cleaning.
Cited alongside this record in an Ask answer
NYC-WTC_000148952
Table listing volatile organic compound (VOC) sampling sites and dates outside of Ground Zero from September 2001 to January 2002.
Cited alongside this record in an Ask answer