• Electrical equipment and lines should be considered energized unless tested and determined otherwise.

• Energized parts must be insulated or guarded from employee contact and any other conductive object.

• Extension cords used with portable electrical tools and appliances must be the three- wire grounded type and connected to a GFI (Ground Fault Interrupter) circuit.

• Extension cords: - Should be protected from accidental damage.

- Should not be fastened with staples, hung from nails, or suspended by wire (tape is an acceptable alternative).

• Portable electrical hand tools should meet the following requirements:

- Should be equipped with a 3-wire cord having a ground wire permanent fixed to the tool frame; or

- Should be of double-insulated type and labeled as such.

• For circuits over 600 volts, if electrical disconnects are not visible and open or locked out, the following requirements should be met:

- Circuits to be de-energized are clearly identified and isolated from all energy sources.

- - Notification received from a designated employee that all switches and disconnectors that could supply energy have been de-energized, locked out, and plainly tagged to show men at work.

- Visual inspections and tests made to assure de-energizing of lines and equipment.

- Protective grounds applied to disconnected lines or equipment.

- Separate tag and lockout attached for each crew requiring de-energizing of same line or equipment.

o Tags and lockouts should not be removed from completed work until designated employees report that all crew members are clear and protective grounds they installed have been removed.

NYC-WTC 000104876

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000104876Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →