NYC-WTC_000128550
Asbestos inspection report notification form submitted to NYC DEP for 102-104 Greenwich Street.
17 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗Facsimile cover sheet transmitting documents regarding environmental work at 102 Greenwich Street.
NYC-WTC_000104853–000104885Folder label: “102 GREENWICH STREET Block: 53 Lot: 37 BIN:1001054 104 Greenwich Street”

OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
placed around the pipe at each end where the glove bag will be attached. This permits a good surface to which to seal the ends of the glove bag, and it minimizes the chance of releasing fibers when the tape at the ends of the glove bag is peeled off at the completion of the project.
1. Slit the top of the glove bag open (if necessary) and cut down the sides to accommodate the size of the pipe (about two inches longer than the pipe diameter).
2. Place the necessary tools into the pouch locate inside the glove bag. This will usually include the bone saw, utility knife, rags, scrub brush, wire cutters, tin snips and pre-cut wettable cloth. Cut out a donut shape in the cloth with the inner diameter one-half inch small than the diameter of the pipe beneath the insulation. The outer diameter of the donut should be three inches longer than the diameter of the pipe insulation being removed. Finally, cut a slit in each of the two donuts so then can be slipped around the pipe. A piece of cloth that can be easily bent around the surface to be cleaned may be used instead of the donut-shaped cloth.
3. One strip of duct tape shall be placed along the edge of the open top slit of the glove bag for reinforcement.
4. Place the glove bag around the section of pipe to be worked o and staple the top together through the reinforcing duct tape. Staple at intervals of approximately one inch. Next, fold the stapled top flap back and tape it down with a strip of duct tape. This should provide an adequate seal along the top. Next, duct tape the ends of the glove bag to the pipe itself, previously covered with polyethylene or duct tape (see (d) 1 above). The bottom seam of the glove bag shall be sealed with high quality duct tape or equivalent to prevent any leakage from the bag that may result from a defect in the bottom seam.
5. Before the commencement of the abatement work, but after the glove bag is attached, the contractor shall smoke test each glove bag to ensure that it does not leak. The asbestos safety technician shall personally witness the smoke testing of each of these glove bags. Using the smoke tube and aspirator bulb or other approved smoke generating device, place the tube into the wetting agent sleeve (two-inch opening to glove bag). Fill the bag with visible smoke. Remove the smoke tube and twist the wetting agent sleeve to close it. While holding the wetting agent sleeve tightly, gently squeeze the glove bag and look for smoke leaking out, especially at the top and ends of the glove bag. If leaks are found, they shall be taped closed using duct tape and the bag shall be re- tested.
Exception: If negative pressure is established and maintained at .02 inches, w.c., smoke testing of glove bags is not required.
NYC-WTC 000104868
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
No available related records indexed in this group.
NYC-WTC_000128550
Asbestos inspection report notification form submitted to NYC DEP for 102-104 Greenwich Street.
17 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗9 shared non-person entities · 1 shared topics · similarity 0.981
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000154680
Application form submitted to the Department of Environmental Protection for notification of an asbestos inspection project.
10 shared non-person entities · 1 shared topics · similarity 0.977
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000112116
NYC DEP emergency notification form documenting an urgent asbestos abatement situation at 250 Vesey Place requiring immediate action.
10 shared non-person entities · similarity 0.971
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000125579
Technical specifications document prepared for asbestos abatement work at the 130 Cedar Street site.
11 shared non-person entities · similarity 0.970
machine-extracted · confidence unavailable · Check page ↗14 shared non-person entities · 1 shared topics · similarity 0.968
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000155525
Initial draft of the comprehensive scope of work required to safely clean 114 Liberty Street following environmental damage.
14 shared non-person entities · 1 shared topics · similarity 0.968
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000135560
Application for permits regarding exterior remediation work at World Trade Center vicinity buildings.
6 shared non-person entities · 1 shared topics · similarity 0.967
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000098577
Contract specifications outlining site decontamination and asbestos disposal procedures for 53 Park Place.
9 shared non-person entities · 1 shared topics · similarity 0.967
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000155460
Submission of a preliminary scope of work document for safely cleaning the 114 Liberty Street building.
13 shared non-person entities · 1 shared topics · similarity 0.966
machine-extracted · confidence unavailable · Check page ↗13 shared non-person entities · 1 shared topics · similarity 0.966
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000107379
Formal request by a resident for the Department of Environmental Protection to perform cleaning and monitoring work at their apartment.
7 shared non-person entities · 1 shared topics · similarity 0.965
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000128550
Asbestos inspection report notification form submitted to NYC DEP for 102-104 Greenwich Street.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Similarity score 0.954 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000128550
Asbestos inspection report notification form submitted to NYC DEP for 102-104 Greenwich Street.
Similarity score 0.941 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Similarity score 0.941 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000128550
Asbestos inspection report notification form submitted to NYC DEP for 102-104 Greenwich Street.
Similarity score 0.938 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000128550
Asbestos inspection report notification form submitted to NYC DEP for 102-104 Greenwich Street.
Similarity score 0.934 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
Review draft of an environmental health and safety plan for debris operations at Staten Island Landfill.
Cited alongside this record in an Ask answer
NYC-WTC_000128550
Asbestos inspection report notification form submitted to NYC DEP for 102-104 Greenwich Street.
Cited alongside this record in an Ask answer
NYC-WTC_000150256
Table of contents for a site control plan document regarding landfill entry and exclusion zones for WTC debris.
Cited alongside this record in an Ask answer
NYC-WTC_000148621
Memo outlining DEP activities including assessment and coordination with federal agencies for street and sidewalk cleaning.
Cited alongside this record in an Ask answer
NYC-WTC_000148952
Table listing volatile organic compound (VOC) sampling sites and dates outside of Ground Zero from September 2001 to January 2002.
Cited alongside this record in an Ask answer