NYC 9/11 Public Portal Document
I
ATC Associates
104 East 25 Street, New York, NY 10010
V
Phone: (212) 353-8280 Fax: (212) 353-8306
Attn: Mr. Benjamin Sallemi
1 Received: 12/13/01 8:00:00 AEI
ATC Associates Inc
1 104 East 25th Street
New York NY 10010
ATC Group 0: 6087
Analysis Date: 12/13/01
Fas: (212) 353-8306 Phone: (212) 353-8280
Project: Tribeca Towers
105 Duane Street, NY, NY
Asbestos Fiber Analysis by Transmission Electron Microscopy (TENT) Performed
by EPA 40 CFR Part 763 Final Rule (AHERA)
Analytical . Asbestos
Area Non Asbestos Structures Sensitivity Concentration
Sample Volume .-lnalybed Asb Type(s) Q5 5 5a (S/cc) (S/mm=) (S/cc) Notes
' 1
6087 -1
1300.00 0.0674 0 None Detected 0 0 0.0044 <14.83 <0.0044
2 0.0674 None Detected 0.0044
1300.00 0 0 0 <14.33 <0.0044 -
6087 -2
1300.00 0.0674 0 None Detected 0 0 0.0044 <14.33 <0.0044
6087 -3
4 1300.00 0.0674 0 None Detected 0 0 0.0044 < 14.83 <0.0044
6087 -4
- - - -------- -- -------- ------ -- -- - -
5 1300.00 0.0674 0 None Detected 0 0 0.0044 <14.33 <0.0044
6057 -5
- - - ------ -- ---
6 1300.00 0.0674 0 None Detected 0 0 0.0044 <14.83 <0.0044
6087 -6
1300.00 0.0674 0 None Detected 0 0 0.0044 < 14.83 <0.0044
6087 -7
8 1300.00 0.0674 0 None Detected 0 0 0.0044 <14.33 <0.0044
I 6087 -8
I
M.ARK PEYSAKHOV MICHAEL A. GORYCKI, Ph.D.
Analyzed by: G r✓0 ' A roved by:
iJ ~n n
Disciaimer. The laboratory is not responsible for data reported in structureslcc, which is dependent on volume collected by non laboratory personnel. This lab is only responsible
for data reported in structuresimm' This report may not be reproduced, except in full, without written approval by ATC Associates Inc. This report may not be used to claim
product endorsement by NVLAP or any other agency of the U.S. Government This reports relates only to the samples reported above. Quality control data (including 95%
confloence limits and laboratory and analysis accuracy and precision is availaoie upon request.
Accredited ror NVLAP P!Ml/TE:V1;101187-0. NY Slate ELAP #10879
NYC-WTC 000104499