NYC 9/11 Public Portal Document
ATC Associates
104 East 25 Street, New York, NY 10010
Phone: (212) 353-8280 Fax: (212) 353-8306
Attn: Mr. Fred Burkhardt
Received: 11/29/01 7:00:00 AM
ATC Associates Inc
104 East 25th Street ATC Group #: 5992
New York NY 10010 Analysis Date: 11/29/01
Fax: (212) 353-8306 Phone: (212) 353-8280
Project: Tribeca Towers
400 Chambers St.
Asbestos Fiber Analysis by Transmission Electron Microscopy (TEM) Performed
by EPA 40 CFR Part 763 Final Rule (AHERA)
Analytical Asbestos
Area Non Asbestos Structures Sensitivity Concentration
Sample Volume Analyzed Ash Type(s) (S/cc)
0.5p-5 Sa (S/mm) (S/cc) Notes
3 1300.00 0.0674 0 None Detected 0 0 0.0044 < 14.83 <0.0044
5992 -I
4
1300.00 0.0674 0 None Detected 0 0 0.0044 < 14.83 <0.0044
5992 -2
5 1300.00 0.0674 0 None Detected 0 0 0.0044 < 14.83 <0.0044
5992 -3
6 1300.00 0.0674 0 None Detected 0 0 0.0044 < 14.83 <0.0044
5992 -4
7 1300.00 0.0674 0 None Detected 0 0 0.0044 <14.83 <0.0044
5992 -5
1300.00 0.0674 0 None Detected 0 0 0.0044 < 14.83 <0.0044
5992 -6
IU 1300.00 0.0674 0 None Detected 0 0 0.0044 < 14.83 <0.0044
5992 -7
Il 1300.00 0.0674 0 None Detected 0 0 0.0044 < 14.83 <0.0044
5992 -8
MARK PEYSAKHOV MICHAEL A. GORYCKI, Ph.D.
Analyzed by:
Approved by:
Disclaimer. The laboratory is not responsible for data reported in structures/cc, which is dependent on volume collected y non-laboratory
personnel. This lab 1 only responsible
for data reported in structures/mm2. This report may not be reproduced, except in full, without written approval by ATC Associates
Inc. This report may not be used to claim
product endorsement by NVLAP or any other agency of the U.S. Government This reports relates only to the samples reported
above. Quality control data (including 95%
confidence limits and laboratory and analysis accuracy and precision) is available upon request
Accredited for NVLAP PLM/TEM #101187-0, NY State ELAP #10879
NYC-WTC 000102819
OCR can misread numbers and units. Confirm readings against the page image before using them.