NYC 9/11 Public Portal Document TESTWELL LABORATORIES, INC. Environmental Laboratory NYSELAP#11142 47 Hudson Street, Ossining, New York 10562 NVLAP # 200083-o AlHA # 100147 CERTIFICATE OF LABORATORY ANALYSIS FOR ASBESTOS CONTENT CLIENT: Bovis Land Lease - LMB Project No: MBO-025AB • Collected By: Boris Feldman Date Sampled: 09/28/01 Date Analyzed: 09/29/01 PROJECT: Millenium Hilton Hotel PLM Analyst: J. Sudol Church Street TEM Analyst: N/A i New York, New York

NUMBER: LAB ID # DESCRIPTION IMATRIXI RESULTS (%)

Floor 45-Room 4505-Dust on Floor Cellulose=10% Non-Fibrous=50% 31 01PLM # 8062 Friable • and Furniture Fiberglass=40%

Floor 45-Elevator Lobby-Dust on Cellulose=20% Non-Fibrous=50% 32 01PLM # 8063 Friable Floor and Furniture Fiberglass=30%

Floor 45-Iroom 4503-Dust on Floor Cellulose=20% Non-Fibrous=50% •

33 01PLM # 8064 Friable and Furniture Fiberglass=30%

Floor 44-Room 4404-Dust on Floor Cellulose=20% Non-Fibrous=50% 34 01PLM # 8065 Friable and Furniture Fiberglass=30%

Li Floor 44-Room 4410-Dust on Floor Cellulose=30% Non-Fibrous=40% 35 01PLM # 8066 Friable and Furniture Fiberglass=30%

Floor 44-Elevator Lobby-Dust on Cellulose=40% Non-Fibrous=10% 36 01PLM # 8067 Friable Floor and Furniture Fiberglass=50% •

Floor 43-Room 4302-Dust on Floor Cellulose=20% Non-Fibrous=40% 37 01PLM # 8068 Friable and Furniture Fiberglass=40%

Floor 43-Elevator Lobby-Dust on Cellulose=20% Non-Fibrous=30% 38 01PLM # 8069 Friable Floor and Furniture Fiberglass=50% •

Floor 43-Room 4310-Dust on Floor Cellulose=40% Non-Fibrous--40% 39 01PLM # 8070 Friable and Furniture Fiberglass=20%

Floor 42-Ice Machine-Dust on Floor 40 01PLM # 8071 Friable Non-Fibrous=80% Fiberglass=20% and Furniture

(1) Sample Information provided on chain of custody assumed correct (2) Samples homogenized by mortar & pestle prior to analysis. (3) Results only pertain to those items tested. (4) The laboratory has non control over sample collection. This certificate of analysis shall not be reproduced expect in full, without the written approval of Testwell Laboratories, Inc.

• •) NVLA Deborah McCaM.aboratorres Dkecior AIHA (as it pertains to bulk sample analysis under certification 200083-0) This report and use of above logos must not be used to claim endorsement by A/HA, NVLAP, N/ST or any other Federal or State regulatory agencies

S

NYC-WTC 000103912

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000103912Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →