NYC 9/11 Public Portal Document
L
TESTWELL LABORATORIES, INC.
• Environmental Labs`-story NYS ELAP # 11142
47 Hudson Street, Oss....ng, New York 10562 NVLAP s 200083-0
AIHA # 100147
CERTIFICATE OF LABORATORY ANALYSIS FOR ASBESTOS CONTENT
CLIENT: Bovis Lend Lease - LMB Project No: MBO-025AB
• 200 Park Avenue Collected By: T. Chhetry
New York, New York Date Sampled: 05/31/02
Date Analyzed: 06/14/02
PRO]ECT: Millenium Hilton Hotel @ WTC PLM Analyst: V. Binchkauskas
55 Church Street TEM Analyst: N/A
New York, New York 10007
•
NUMBER: I LAB ID # DESCRIPTION IMATRIXI RESULTS %
First Floor / Main Lobby - Dust in Chrysotile = 0.52% Cellulose = 29.84%
1 02PLM # 4151 Friable Fiberglass = 19.2% Other = Trace
Plenum Space Wall
Non-Fibrous = 50.52%
First Floor / Main Lobby - Dust in Chrysotile = Trace Cellulose = 35%
2 02PLM # 4152 Friable Fiberglass = 15% Other = Trace
Plenum Space Center
Non-Fibrous = 50%
3rd Floor / Dust on Hung Ceiling by Cellulose = 30% Fiberglass = 40/c
3 02PLM # 4153 Friable
the Bar Non-Fibrous =30%
3rd Floor / Dust on Hung Ceiling Chrysotile = 0.25% Cellulose '= 10.13%
4 02PLM # 4154 Friable Fiberglass = 40% Other = Trace
Boardroom
Non-Fibrous = 49.62%
4th Floor / Dust on Hung Ceiling Cellulose = 5% Fiberglass = 15%
5 02PLM # 4155 Friable
Boardroom Non-Fibrous = 80%
4th Floor / Dust on Hung Ceiling in Chrysotile = Trace Cellulose = 20%
6 02PLM # 4156 Friable
Tribeca Conference Room Fiberglass = S0% Non-Fibrous = 30%
4th Floor / Dust on Hung Ceiling in Cellulose = 5% Fiberglass = Trace
7 02PLM # 4157 Friable
Chelsea Dining Room Non-Fibrous = 95%
(1) Sample Information provided on chain of custody assumed correct (2) Samples homogenized by mortar & pestle prior to
analysis. (3) Results only pertain to those items tested. (4) The laboratory has non control over sample collection. This
certificate of analysis shall not be reproduced expect in full, without the written approval of Testwell Laboratories, Inc.
.. .... ....... Deborah Mccarl-LaboratoriDirector
AIHA (as it pertains to bulk sample analysis under certification 200083-0)
This report and use of above logos must not be used to claim endorsement by AIHA, NVLAP, NISI or any other Federal or State
regulatory agencies
--I
NYC-WTC 000103697