NYC 9/11 Public Portal Document
Ii
L TESTWELL LABORATORIES, INC.
Environmental Laboratory
47 Hudson Street, Ossining, New York 10562
NYSELAP#11142
NVAP#200083-0
AIHA #100147
S
PCM AIR SAMPLE RESULTS
Client: Bovis Lend Lease Date Collected: 02/15/02
Date Rec'd (lab): 02/16/02
Project #: MBO-025AB Analysis Date: 02/16/02
Analyst: L. Chivarini
Sample Location: The Millenium Hilton
o
55 Chruch Street Analytical Method: NIOSH 7400
New York, New York
Field Technician: K. Laverenko/S. Manukov
Sample #: Sample Location: Sample
Type
—Work
Location
02PCM #J Volume
Duration Concentration
(min.) f/cc
_._._.R. B_yine_.....--..... Personal
03Pers Scaffold 2888 450 180 0.0060
PII TW Entire
08Pers -----R=gyine.-.-.-.-.-.- Personal Scaffold
2893 480 200 0.0056
PII TWA Entire
11 Blank Blank N/A 2896 0 0 N/A
12 Blank Blank N/A 2897 0 0 N/A
Total Duration Sampled (min.) 380
8 hr. Time Weighted Average (TWA) 0.0046
(c)
Permissible exposure limits (PELS)
(c)(2) Excursion limit. The employer shall ensure that no employee Is exposed to an airborne concentration of asbestos in excess of 1.0 fiber per cubic
centimeter of air (1 f/cc) as averaged over a sampling period of thirty (30) minutes, as determined by the method prescribed in Appendix A to this section, or
by an equivalent method.
(c)(2) Excursion limit The employer shall ensure that no employee exposed to an airborne concentration of asbestos in excess of 1.0 fiber per cubic
is
centimeter of air (1 f/cc) as averaged over a sampling period of thirty (30) minutes, as determined by the method prescribed in Appendix A to this section, or
by an equivalent method.
S
Respiratory Protection: Half face negative air respirator equip with HEPA cartridge.
Limit of quantitation based on volume of air collected and 5.5 f/100 fields as per the NIOSH 7400 method. The report value is
calculated by using the higher value of either the actual concentration or the limit of quantification reported at P(0.05) indicating the 95%
confidence level at 2 standard deviations. " Sample Information is provided by the client & presented as stated. •** Laboratory QC
data available upon request. -- The laboratory has no control over air sampling collection. Reports are the confidential property of our
o
clients. This certificate of analysis/report shall not be used by the client to claim product endorsement by the National Voluntary
Laboratory Approval Program (NVLAP) or any agency of the United States Government. This certificate of analysis/report shall not be
• reproduced except in full, without the written approval of Testwell Laboratories, Inc.