NYC Law Department release
Independent mirror · updated as the City releases more · v1.2.6
← Document results/DEP Box 36/No folder label
Document / 262 pages

PCM air sample results chain of custody, 200 Park Avenue

Machine-extracted title · confidence 85%

Chain of custody forms for personal protective equipment and air sampling results conducted at 200 Park Avenue by Testwell Laboratories.

NYC-WTC_000103205–000103466
Page image
Scanned page image, NYC-WTC_000103264
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

L TESTWELL LABORATORIES, INC. Environmental Laboratory NYSEW111142

ii 47 Hudson Street, Ossining, New York 10562 Iwi- a

200083-o AIHA * I00147

PCM AIR SAMPLE RESULTS Client: Bovis Lend Lease Date Collected: 05/24/02 Date Rec'd (lab): 05/26/02 • Project #: MBO-025AB Analysis Date: 05/28/02 Analyst: D. McCar/ Sample Location Millenium Hilton @ WTC 55 Chruch Street Analytical Method: NIOSH 7400 New York, New York Various Floors Sample Condition Acceptable? YES Field Technician T. Chhetry — — —

Sample Concentration Sample #: Sample Location: Type 02PCM Volume f/cc

Outside Work Area Clean Room of During 14430 1350 0.0067 315 Remote Personal Decon Outside Work Area Remote Wane 316 During 14431 1350 OVERLOAD Decon Outside Work Area 46th Floor Inside During 14432 1350 0.0054 317 Airlock Outside Work Area 46th 318 Floor During 14433 1350 OVERLOAD Freight Elevator Lobby - Outside Work Area 45th Floor Inside 319 During 14434 1350 0.0076 . Airlock Outside Work Area 45th 320 Floor During 14435 1350 0.0064 Freight Elevator Lobby Outside Work Area 44th Floor Inside 321 During 14436 1350 0.0051 Airlock Outside Work Area 44th 322 Floor During 14437 1350 OVERLOAD Freight Elevator Lobby 323 Field Blank Blank 14438 0 N/A

324 Field Blank Blank 14439 0 N/A • Limit of quantitation based on volume of air collected and 5.5 f/100 fields as per the NIOSH 7400 method. The report value is calculated by using the higher value of either the actual concentration or the limit of quantification reported at P(0.05) indicating the 95% confidence level at 2 standard deviations. ** Sample information is provided by the client & presented as stated. "' Laboratory QC data available upon request "" The laboratory has no control over air sampling collection. Reports are the confidential property of our clients. This certificate of analysis/report shall not be used by the client to claim product endorsement by the National Voluntary Laboratory Approval Program (NVLAP) or any agency of the United States Government This certificate of analysis/report shall not be reproduced except in full, without the written approval of Testwell Laboratories, Inc.

Deborah McCart - Laboratory Director

Page 1 of 1

NYC-WTC 000103264

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000103264Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →