NYC 9/11 Public Portal Document
L
1[
1
TESTWELL LABORATORIES, INC.
Environmental Laboratory
47 Hudson Street, Ossining, New York 10562
UYs E AP # 11142
rr1aPx20008-0
F:HA # 100147
PCM AIR SAMPLE RESULTS
•
Client: Bovis Lend Lease Date Collected: 02/12/02
Date Rec'd (lab): 02/13/02
Project #: MBO-025AB Analysis Date: 02/13/02
Analyst: D. Agaresf
Sample Location: The Millenium Hilton
55 Chruch Street Analytical Method: NIOSH 7400
New York, New York
Field Technician: K. Laverenko/S. Manukov
Sample _Work Duration Concentration
Sample #: Sample Location: 02PCM # Volume
Type Location
I (min.) f/cc
Joseph Puntillo Personal Entire
07Pers --'--------- ------------ 2607 75 30 0.0360
_ Pu_ STEL Building
Joseph Puntillo Personal Entire
08Pers ------- ------------------- 2608 300 120 0.0097
PII TWA Building
0
20 Blank Blank N/A 2620 0 0 N/A
21 Blank Blank N/A 2621 0 0 N/A
Total Duration Sampled (min.) 150
Short Term Exposure Limit (STEL) 0.036(
8 hr. Time Weighted Average (TWA) 0.004
(c) Permissible exposure limits (PELS)
(c)(2) Excursion limit. The employer shall ensure that no employee is exrosed to an airborne concentration of asbestos in excess of 1.0 fiber per cubic
centimeter of air (1 f/cc) as averaged over a sampling period of thirty (20) minutes, as determined by the method prescribed in Appendix A to this section. or
by an equivalent method.
(c)(2) Excursion limit. The employer shall ensure that no employee is exresed to an airborne concentration of asbestos in excess of 1.0 fiber per cubic
centimeter of air (1 f/cc) as averaged over a sampling period of thirty (30) minutes, as determined by the method prescribed in Appendix A to this section. or
S by an equivalent method.
Respiratory Protection: Half face negative air respirator equip with HEPA cartridge.
' Limit of quantitation based on volume of air collected and 5.5 f/100 fields as per the NIOSH 7400 method. The report value is
.4
calculated by using the higher value of either the actual concentration or the limit of quantification reported at P(0.05) indicating the 95%
confidence level at 2 standard deviations. " Sample information is provided by the client & presented as stated. "' Laboratory QC
data available upon request. "" The laboratory has no control over air sampling collection. Reports are the confidential property of our
clients. This certificate of analysis/report shall not be used by the client to claim product endorsement by the National Voluntary
Laboratory Approval Program (NVIAP) or any agency of the United States Government. This certificate of analysis/report shall not be
reproduced except in full, without the written approval of Testwell Laboratories, Inc.
77
Deborah McCall - Laboratory Director
NYC-WTC 000103586
OCR can misread numbers and units. Confirm readings against the page image before using them.