PCM AIR SAMPLE RESULTS
Client: Bovis Lend Lease Date Collected: 06/10/02
Date Rec'd (lab): 06/11/02
Project #: MBO-025AB Analysis Date: 06/11/02
_ _ Analyst: D. McCarl _
• Sample Location: The Millenium Hilton
55 Chruch Street Analytical Method: NIOSH 7400
New York, New York
Field Technician: B. Gitman
Sample #: Sample Location: Sample Type 02PCM # Volume Concentration f/cc
555 36th Floor inside airlock During 16090 1150 0.0053
is 556 36th floor freight elevator lobby During 16091 1150 0.0034
557 37th Floor inside airlock During 16092 1150 0.0026
558 37th floor freight elevator lobby During 16093 1150 0.0073
559 Field Blank During 16094 N/A N/A
560 Field Blank During 16095 N/A N/A
Limit of quantitation based on volume of air collected and 5.5 f/100 fields as per the NIOSH 7400 method. The report
value is calculated by using the higher value of either the actual concentration or the limit of quantification reported at
P(0.05) indicating the 95% confidence level at 2 standard deviations. ** Sample information is provided by the client &
presented as stated. "` Laboratory QC data available upon request. "" The laboratory has no control over air
sampling collection. Reports are the confidential property of our clients. This certificate of analysis/report shall not be
used by the client to claim product endorsement by the National Voluntary Laboratory Approval Program (NVLAP) or
any agency of the United States Government. This certificate of analysis/report shall not be reproduced except in full,
without the written approval of Testwell Laboratories, Inc.