FEB-14-02 11:09 FROM-PACE ANALYTICAL 612-607-6444 T-452 P.02/04 F-677
1700 Elm Street - Suite 200
Minneapolis, MN 55414
TM
11/_i aceAnalvocal Method 23 Analysis Results Tel: 612.807-1704
Fax RI 2- R07-6444
Client - ATC
Client's Sample ID P-1 CHAMBERS ST
Lab Sample ID 103286951
Filename F20212B_06 Matrix PUF
Injected By BAL Dilution NA
Amount Extracted 421.92 m3 Collected 01/23/2002
ICAL Date 01/25/2002 Received 01/25/2002
CCal Filename(s) F20212B_02 Extracted 01/29/2002
Method Blank ID BLANK-1441 Analyzed 02/13/2002 00:34
Native Conc EMPC LRL Internal ng's Percent
Isomers pg/m3 pg/m3 pg/m3 Standards Added Recovery
2,3,7,8-TCDF 0.015 ----- 0.0065 JA 2,3,7,8-TCDF-13C 2.00 80
Total TCDF 0.470 ----- 0.0047 2,3,7,8-TODD-13C 2.00 82
1,2,3,7,8-PeCDF-13C 2.00 90
2,3,7,8-TCDD ----- 0.0076 0.0047 I 1,2,3,7,8-PeCDD-13C 2.00 .97
Total TODD 0.500 ----- 0.0047 1,2,3,6,7,8-HxCDF-13C 2.00 81
1,2,3,6,7,8-HxCDD-13C 2.00 77
1,2,3,7,8-PeCDF ND ----- 0.0240 1,2,3,4,6,7,8-HpCDF-13C 2.00 71
2,3,4,7,8-PeCDF ND ----- 0.0240 1,2,3,4,6,7,8-HpCDD-13C 2.00 74
Total PeCDF 0.072 ----- 0.0240 J OCDD-13C 4.00 63
1,2,3,7,8-PeCD0 NO ----- 0.0240 Recovery
Total PeGDD 0.046 ----- 0.0240 J Standards
1,2,3,4-TCDD-13C 2.00 NA
1,2,3,4,7,8-HxCDF ND --•-- 0.0240 1,2,3,7,8,9-HxCDD-13C 2.00 NA
1,2,3,6,7,8-HxCDF ND ----- 0.0240
2,3,4,6,7,8-HxCDF ND ---- 0.0240 Surrogates
1,2,3,7,8,9-HxCDF ND ----- 0.0240 2,3,7,8-TCDD-37CI4 2.00 103
Total HxCDF 0.029 -- --
0.0240 J 2,3,4,7,8-PeCDF-13C 2.00 105
1,2,3,4,7,8-HxCDF-13C 2.00 112
1,2,3,4,7,8-HxCDD NO 0.0240 1,2,3,4,7,8-HxCDD-13C 2-00 128
99
--
--
1,2,3,6,7,8-HxCDD ND ----- 0.0240 1,2,3,4,7,8,9-HpCDF-13C 2.00
1,2,3,7,8,9-HxCDD ND ----- 0.0240
Total HxCDD 0.050 ----- 0.0240 J
1,2,3,4,6,7,8-HpCDF ND ----- 0.0240 Total 2,3,7,8-TCDD
1,2,3,4,7,8,9-HpCDF ND ----- 0.0240 Equivalence: 0.0021 pg/m3
Total HpCDF ND ----- 0.0240 (Using ITE Factors)
1,2,3,4,6,7,8-HpCDD 0.046 ----- 0.0240 J
Total HpCDD 0.091 ----- 0.0240 J
OCDF ND ---- 0.0470
OCDD 0.170 ----- 0.0470 J
Conc = Concentration (Totals Include 2,3,7,8-substituted isomers). I = Interference
EMPC = Estimated Maximum Possible Concentration E = PCDE Interference
LRL = Lower Reporting Limit S = Saturated signal
J = Concentration detected is below the calibration range NO = Not Detected
S n Less than 10 times higher than method blanl level NA = Not Applicable
P = Recovery outside of target range NC = Not Calculated
Nn = Value obtained from additional analysis
A = Detection Limit based on signal to noise
Report No.....02-1053453
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except In full,
without the written consent of Pace Analytical Services, Inc.
NYC-WTC 000102869