NYC 9/11 Public Portal Document
Page 1 of I Personal Air Monitoring
Airborne Fibers
Client: ETS Contracting, Inc. Nikon Labophot PCM
FINAL-AIRE Project:
Address:
PEP
114 Liberty Street
Serial No.: 241205
Field Area: 0.00785 mm2
Environmental Consultants
Project Location 1ie Floor Filter Area: 385 mm2 •
Date Sampled: 04/02/03 PO No: Methods NIOSH 7400•AN
Tel: I7I'' 646-0925 Date Received: 04/12/03 Job No: 1286/03 ELAP ID No.: 11228
Fax .1181646- 825 Date Analyzed: 04/12/03 Rotometer No:
ID Type Volume(L) Individual Social Security Activity Respirator Fibers $hrTWA EXC
Flow I m No IFINd f/cc flcc
01 EXC 75/2.5 A. Hrabovcak REM HM 0.220 0.14
02 PRS 1200/2.5 J. Jankowski I I 1 REM HM 0.360 0.015
03 PRS 1203/2.5 O. Kriz REM HM 0.290 0.012
04 PRS 1205/2.5 M. Kiernozek REM HM 0.305 0.012
05 ELK 0.020
06 ELK 0.015
Final-Aire is responsible for only the fibers per field as described in NIOSH 7400
Comments:
Sampled by: M. Jendroska
Fiber Range Relative Standard Deviation
1-20 0.32 Analyzed by: Nicholas Anastasakos
21-50 0.17
51-100 0.12 Approved by:
>100 0.08
EXC: F,:cuninn 1,Imit HM: Half-Face FF: Full-Race. PAPR: Powered Air Technical Director
PRS: Personal ENV: Environmental CL: Clearance WP: Wet Wipe
REM: Gross Removal GLB: Glovebag CLN: Cleaning BRE: Bag Removal T: Transite
m1151 G.. ,. '7 1.1. MV 1 1 0 0
NYC-WTC 000100776