ASBESTOS ANALYTICAL REPORT
1
ASBESTOS CONTROL PROGRAM LABORATORY
96-05 HORACE HARDING EXPRESSWAY
CORONA, NEW YORK 11368
(718) 595-6309 FAX# (718) 595-6307
ELAP # 11045
TEST METHODS : 1) 40 CFR Part 763, Subpart F, App. A
2) Polarized Light Microscopy plus Stratified Point-Counting Method
3) EPA/600/R-93/116
Incident #: WTC122302 Date Collected: 12/23/02
Inspector : R. RAMMOHAN Received: 12/23/02
Premise 139 FULTON STREET Analyzed: 12/27/02
Boro Manhattan
Analyst G. FRUCHTMAN
Client #:
DEP Sample #: 21223/A078005 21223/A078007 21223/A078008
Laboratory #: 21223/123 21223/1.25 21223/126
Location Sampled: 912 N. WINDOW 910(C) &. WINDOW 918(B) W. WINDOW
Color: GREY GREY GREY
Homogenous: Yes Yes Yes
Asbestos Present: Yes Yes Yes
Reaulta (t)
Chrysotile <1 Chrysotile trace Chrysotile trace
Cellulose 2 Cellulose 6 Cellulose 2
Fibrous glass44 Fibrous glass4l Fibrous glass43
Other <1 Matrix 53 Matrix 55
Matrix 54
Comments:
Reviewed by:
Laboratory Direct
This test report may not be reproduced except with the written approval of this
laboratory. The test report relates only to the item (s) listed and does not represent a
product endorsement by NVLAP or any other U.S. Government agency.