Asbestos bulk sample analysis summary, 225 Liberty Street, 2001-2002

Machine-extracted title · confidence 95%

Summary of 94,014 asbestos samples collected and analyzed at 225 Liberty Street between September 2001 and January 2002.

NYC-WTC_000097285–000097303

Folder label: “225 LIBERTY STREET Block: 16 Lot: 125 BIN: 1000058 2 World Financial Center

Page image
Scanned page image, NYC-WTC_000097293
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

SCIENTIFIC1J ORATORIES,INC, 117 EAST 30TH STREET NEW YORK,NY 10016 FULL sssvlcg

sWIRoNMRNFAL uaoa

uYoatas TEL: (212)679-8600•FAX:(212)679-9392

PLM Bulk Asbestos Report Independent Monitoring & Analysis, Inc. Date Received 03/23/2002 SciLab Job No. 202033340 Attn: Peter Ellanis Date Examined 03/23/2002 P.O. # Ellams 511 6th Ave. ELAPNumber 11480 Page 4 of 4 Suite 353 RE: World Final icial Center - Towers A,B,C, and D New York, NY 10012

Client No. / HGA Lab No. Asbestos Present Total % Asbestos WFC-13 202033340-13 Yes 1,2 <1% <l.% Location: Tower D, 4th Floor - Southwest End Window Ledge

Description: Grey, Heterogeneous, Bulk Material Asbestos Types: Chrysotile Trace Other Material: Cellulose 15. %, Fibrous glass 35. %, Non -fibrous 50. %

WFC-14 202033340-14 Yes 1.2 <l% Location: Tower D, Northeast End Balcony Below Window Ledge

Description: Grey, Heterogeneous, Bulk Material Asbestos Types: Chrysotile Trace Other Material: Cellulose 10. %, Fibrous glass 20. %, - Synthetic fibers Trace, Non-fibrous 70. %

WFC-15 202033340-15 Yes <1% 1,2 Location: Tower D, 4th Floor - Southwest End Window Ledge

Description: Grey, Heterogeneous, Bulk Material Asbestos Types: Chrysotile Trace Other Material: Animal hair Trace, Cellulose 15. %, Fibrous glass 30. %, Synthetic fibers Trace, Non-fibrous 55. %

Reporting Notes: (1) PLM analysis by EPA 400 Point Count Method, where Trace = less than 1% by weight (e.g. < 1.0%) (2) Composite analysis results for heterogenous debris samples may be highly variable due to inhomogenities in materials present

NYC-WTC 000097293

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000097293Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →