NYC Law Department release
Independent mirror · updated as the City releases more · v1.2.6
← Document results/DEP Box 33/125 Cedar
Document / 17 pages

Pre-bid meeting notice for 125 Cedar Street cleaning

Machine-extracted title · confidence 90%

Notice of a mandatory pre-bid meeting and scope for asbestos abatement at 125 Cedar Street in August 2002.

NYC-WTC_000097066–000097082

Folder label: “125 Cedar

Page image
Scanned page image, NYC-WTC_000097069
OCR text

OCR status: ok · source: pdftotext

NYC 9111 Public Portal Document

Sampling and Analytical Procedures for Lead, PAHs, Dioxin, Fibrous Glass, Silica, and Mercury

1 . Sampling fur lead, PAHs, dioxin, fibrous glass, crystalline silica and mercury shall be performed by the wipe sampling technician. A completed chain of custody must accompany all samples. A unique sample number shall be assigned to each sample. A complete written description and/or diagram shall clearly identify each sampling location.

2. Post cleaning air samples for fibrous glass and silica shall be collected concurrently with the asbestos clearance air sampling procedures specified herein. Five samples for fibrous glass and one sample for silica shall be collected in each apartment.

3. Wipe samples shall be collected before and after cleaning for lead, mercury, dioxin, and PAHs.

Prior to the cleaning activities, three wipe samples shall be collected for each of these parameters in each apartment. The sampling locations shall be a wall, a bare floor, and a counter or tabletop.

Ajier cleaning activities, three wipe samples shall be collected for each of these parameters in each apartment. The sampling locations shall be a wall, a bare floor, and a counter or tabletop; preferably at the same location as the pre-cleaning samples.

4. The required sampling and analytical procedures are specified in Table 1.

Table 1: Sun lin and Anal plical Methods Parameter Description SamplingMethodology Analytical Method Lead Wipe samples HUD Appendix 13.1 EPA Method SW-846-601OB PAHs Wipe samples ASTM D6661-01 ASTM-6661-01 EPA SW-846-8270C Dioxin Wipe samples ASTM 6661-01 ASTM 6661-01 EPA Method SW-846-8290 Fibrous Glass Air samples NIOSH 7400 NIOSH 7400, Counting Method "B" Crystalline Silica Air samples NIOSH 7500 N1OSH 7500 (XRD) Merc y Wipe samples HUD Appendix 13.1 EPA Method SW-846 7471A

Asbestos Air Sample Collection and Analysis

1. All asbestos air samples collected during clean-up activities shall be analyzed via TEM. The method of analysis and sampling methodologies shall be in accordance with the applicable sections of Title 15, Chapter 1 of the Rules of the City of New York. and AHERA.

2. A turnaround tune of 24 hours is required for all samples. Failure to do so will result in nonpayment.

Asbestos clearance air samples shall be analyzed in accordance with the NIOSH 7400 Method, and analyzed by PCM followed by TEM The laboratory shall report a PCMe value of all fibers greater than 5 microns in length. Therefore, the lab shall report PCM, TEM and PCMe values for each sample. 3 of 5

NYC-WTC 000097069

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000097069Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →