NYC-WTC_000107838
Document excerpt detailing work specifications for asbestos cleanup activities at 125 [name].
10 shared non-person entities · 1 shared topics · similarity 0.988
machine-extracted · confidence unavailable · Check page ↗Notice of a mandatory pre-bid meeting and scope for asbestos abatement at 125 Cedar Street in August 2002.
NYC-WTC_000097066–000097082Folder label: “125 Cedar”

OCR status: ok · source: pdftotext
NYC 9111 Public Portal Document
Sampling and Analytical Procedures for Lead, PAHs, Dioxin, Fibrous Glass, Silica, and Mercury
1 . Sampling fur lead, PAHs, dioxin, fibrous glass, crystalline silica and mercury shall be performed by the wipe sampling technician. A completed chain of custody must accompany all samples. A unique sample number shall be assigned to each sample. A complete written description and/or diagram shall clearly identify each sampling location.
2. Post cleaning air samples for fibrous glass and silica shall be collected concurrently with the asbestos clearance air sampling procedures specified herein. Five samples for fibrous glass and one sample for silica shall be collected in each apartment.
3. Wipe samples shall be collected before and after cleaning for lead, mercury, dioxin, and PAHs.
Prior to the cleaning activities, three wipe samples shall be collected for each of these parameters in each apartment. The sampling locations shall be a wall, a bare floor, and a counter or tabletop.
Ajier cleaning activities, three wipe samples shall be collected for each of these parameters in each apartment. The sampling locations shall be a wall, a bare floor, and a counter or tabletop; preferably at the same location as the pre-cleaning samples.
4. The required sampling and analytical procedures are specified in Table 1.
Table 1: Sun lin and Anal plical Methods Parameter Description SamplingMethodology Analytical Method Lead Wipe samples HUD Appendix 13.1 EPA Method SW-846-601OB PAHs Wipe samples ASTM D6661-01 ASTM-6661-01 EPA SW-846-8270C Dioxin Wipe samples ASTM 6661-01 ASTM 6661-01 EPA Method SW-846-8290 Fibrous Glass Air samples NIOSH 7400 NIOSH 7400, Counting Method "B" Crystalline Silica Air samples NIOSH 7500 N1OSH 7500 (XRD) Merc y Wipe samples HUD Appendix 13.1 EPA Method SW-846 7471A
Asbestos Air Sample Collection and Analysis
1. All asbestos air samples collected during clean-up activities shall be analyzed via TEM. The method of analysis and sampling methodologies shall be in accordance with the applicable sections of Title 15, Chapter 1 of the Rules of the City of New York. and AHERA.
2. A turnaround tune of 24 hours is required for all samples. Failure to do so will result in nonpayment.
Asbestos clearance air samples shall be analyzed in accordance with the NIOSH 7400 Method, and analyzed by PCM followed by TEM The laboratory shall report a PCMe value of all fibers greater than 5 microns in length. Therefore, the lab shall report PCM, TEM and PCMe values for each sample. 3 of 5
NYC-WTC 000097069
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
No available related records indexed in this group.
NYC-WTC_000107838
Document excerpt detailing work specifications for asbestos cleanup activities at 125 [name].
10 shared non-person entities · 1 shared topics · similarity 0.988
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000108828
Regulatory specifications for asbestos abatement work including PPE requirements and decontamination systems at 125 [name].
11 shared non-person entities · 1 shared topics · similarity 0.988
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000154102
List of contract documents for WTC interior and exterior cleaning work including indemnification boilerplate, bonding requirements, insurance specifications, and general…
10 shared non-person entities · 1 shared topics · similarity 0.987
machine-extracted · confidence unavailable · Check page ↗10 shared non-person entities · 1 shared topics · similarity 0.976
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000112080
Contract exhibit detailing general conditions, bond requirements, and payment terms for the exterior cleanup work at 250 Vesey Place.
6 shared non-person entities · 1 shared topics · similarity 0.975
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000099393
Contract for supply and services related to debris removal at 87 Nassau Street.
6 shared non-person entities · 1 shared topics · similarity 0.974
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000130720
Exhibit B of a supply and service contract detailing general conditions and bond requirements for debris removal work.
6 shared non-person entities · 1 shared topics · similarity 0.974
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000114353
Schedule detailing bond requirements and performance conditions for a supply and service agreement related to site cleanup work.
6 shared non-person entities · 1 shared topics · similarity 0.974
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000094326
Exhibit B containing general conditions and schedule for supply and service contract including performance bond, payment, and labor and material provisions.
6 shared non-person entities · 1 shared topics · similarity 0.974
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000113453
Contract document defining terms for supply and service related to debris cleanup at 1 Water Street.
6 shared non-person entities · 1 shared topics · similarity 0.974
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000111939
Contract exhibit detailing general conditions and bond requirements for the supply and service of debris removal work.
6 shared non-person entities · 1 shared topics · similarity 0.974
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000099050
Administrative form outlining bond articles and financial terms associated with the environmental cleanup project at 94 Nassau Street.
6 shared non-person entities · 1 shared topics · similarity 0.973
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
Page similarity is temporarily unavailable or this page has no indexed vector.
Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000097060
Administrative record containing identification codes and metadata for documents related to 125 Cedar Street in the DEP archive.
Filed in the same folder
NYC-WTC_000097063
Fragmented document excerpt from the 125 Cedar Street folder containing illegible text and identification codes.
Filed in the same folder
NYC-WTC_000097083
Legal firm transmits confidential information regarding environmental work to EPA Region 2 via fax.
Filed in the same folder
NYC-WTC_000097091
Technical specifications detail mold remediation and special handling instructions for specific items in 125 Cedar Street units.
Filed in the same folder
NYC-WTC_000097094
Technical specifications detail mold remediation and special handling instructions for specific items in 125 Cedar Street units.
Filed in the same folder