NYC-WTC_000107838
Document excerpt detailing work specifications for asbestos cleanup activities at 125 [name].
10 shared non-person entities · 1 shared topics · similarity 0.988
machine-extracted · confidence unavailable · Check page ↗Notice of a mandatory pre-bid meeting and scope for asbestos abatement at 125 Cedar Street in August 2002.
NYC-WTC_000097066–000097082Folder label: “125 Cedar”

OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Qualifications
Project Monitoring The Project Monitors must posses valid NYS Asbestos Project Monitor certificates. Monitors must have served as a third party project monitor on at least 25 asbestos abatement projects. Project Monitor must have performed final clearance inspections on at least 25 asbestos abatement projects. A single individual with Asbestos Project Monitor and Asbestos Project Sampling Technician certification shall not perform the functions of both Monitor and Technician during this project.
Air Sampling Technicians Air monitoring technicians must posses valid NYS Asbestos Project Sampling Technician (APST) certificates. Technicians must have performed air sampling for at least 6 months. At a minimum at least 5 Air Sampling Technicians must be assigned to this project. A single individual with Asbestos Project Monitor and Asbestos Project Sampling Technician certification shall not perform the functions of both Monitor and Technician during this project.
Wipe Sampling Technicians Wipe sampling technicians must have 1-year experience in wipe sampling for a variety of contaminants and have received state certified training in dust sampling. At a minimum at least 2 Wipe Sampling Technicians must be assigned to this project.
Equipment Sampling equipment must be in sufficient quantity to provide the amount and type of samples required for this project. At a minimum the following equipment are required: air-sampling pumps with flow rate capacities of 2 to 10 liters per minute, tripods, rotometers, sample cassettes with mixed cellulose ester filters having pore size of 0.8µm, micro vacuum, disposable porous cellulosic towellettes moistened with wetting agent and solvent-wetted sampling agent.
Analytical Laboratory The environmental laboratory must be certified by the New York State Department of Health. Certification for all the analytes specified herein must have been maintained for at least six (6) consecutive proficiency testing rounds. The laboratory must possess a gas chromatograph equipped with a capillary column and high-resolution mass spectrometer for analyzing dioxin and inductively coupled plasma for total metals. Cold Vapor Method apparatus shall be used for mercury analysis.
Proof of qualifications must be presented to the NYCDEP prior to commencement of work. The NYCDEP reserves the right to disqualify any individual(s) from work on this project for non-compliance with these specifications or the requirements of applicable rules and regulations.
Specifications
Although 90 days have been allotted for the contract, it is anticipated that the work will be completed within three (3) weeks.
2 of 5
NYC-WTC 000097067
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
No available related records indexed in this group.
NYC-WTC_000107838
Document excerpt detailing work specifications for asbestos cleanup activities at 125 [name].
10 shared non-person entities · 1 shared topics · similarity 0.988
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000108828
Regulatory specifications for asbestos abatement work including PPE requirements and decontamination systems at 125 [name].
11 shared non-person entities · 1 shared topics · similarity 0.988
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000154102
List of contract documents for WTC interior and exterior cleaning work including indemnification boilerplate, bonding requirements, insurance specifications, and general…
10 shared non-person entities · 1 shared topics · similarity 0.987
machine-extracted · confidence unavailable · Check page ↗10 shared non-person entities · 1 shared topics · similarity 0.976
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000112080
Contract exhibit detailing general conditions, bond requirements, and payment terms for the exterior cleanup work at 250 Vesey Place.
6 shared non-person entities · 1 shared topics · similarity 0.975
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000099393
Contract for supply and services related to debris removal at 87 Nassau Street.
6 shared non-person entities · 1 shared topics · similarity 0.974
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000130720
Exhibit B of a supply and service contract detailing general conditions and bond requirements for debris removal work.
6 shared non-person entities · 1 shared topics · similarity 0.974
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000114353
Schedule detailing bond requirements and performance conditions for a supply and service agreement related to site cleanup work.
6 shared non-person entities · 1 shared topics · similarity 0.974
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000094326
Exhibit B containing general conditions and schedule for supply and service contract including performance bond, payment, and labor and material provisions.
6 shared non-person entities · 1 shared topics · similarity 0.974
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000113453
Contract document defining terms for supply and service related to debris cleanup at 1 Water Street.
6 shared non-person entities · 1 shared topics · similarity 0.974
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000111939
Contract exhibit detailing general conditions and bond requirements for the supply and service of debris removal work.
6 shared non-person entities · 1 shared topics · similarity 0.974
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000099050
Administrative form outlining bond articles and financial terms associated with the environmental cleanup project at 94 Nassau Street.
6 shared non-person entities · 1 shared topics · similarity 0.973
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
Page similarity is temporarily unavailable or this page has no indexed vector.
Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000097060
Administrative record containing identification codes and metadata for documents related to 125 Cedar Street in the DEP archive.
Filed in the same folder
NYC-WTC_000097063
Fragmented document excerpt from the 125 Cedar Street folder containing illegible text and identification codes.
Filed in the same folder
NYC-WTC_000097083
Legal firm transmits confidential information regarding environmental work to EPA Region 2 via fax.
Filed in the same folder
NYC-WTC_000097091
Technical specifications detail mold remediation and special handling instructions for specific items in 125 Cedar Street units.
Filed in the same folder
NYC-WTC_000097094
Technical specifications detail mold remediation and special handling instructions for specific items in 125 Cedar Street units.
Filed in the same folder