NYC 9/11 Public Portal Document
Friday, March 01, 2002 10:34 AM EHI, Inc. 973-729-5649 p.08
Bovis Lend Lease, Inc.
Environmental Hazard Investigation
75 Park Place ` x= - February 22, 2002
-Floors 6, 7, 8, & 9 EHI Project #: 0224-0572A
Area/Sample 01 02 03 04 05 06 07 08
1,2,3,4,7,8-C 16-Dibenzo-p- <0.40 <0.12 <0.12 <0.12 • <0.14 <0.15 <0.14 <0.060
dioxin
1,2,3,6,7,8-C16-Dibenzo-p- <0.36 <0.10 <0.11 <0.10 <0.13 <0.13 <0.12 <0.054
dioxin
1,2,3,7,8,9-C 16-Dibenzo-p- <0.30 <0.11 <0.11 <0.11 <0.13 <0.14 <0.13 <0.057
dioxin
1,2,3,4,6,7,8-C17- <0.26 <0.093 <0.094 <0.070 <0.12 <0.11 <0.10 <0.049
Dibenzofiran
1,2,3,4,7,8,9-C17- <0.31 <0.11 <0.11 <0.093 <0.14 <0.13 <0.12 <0.058
Dibenzofuran
1,2,3,4,6,7,8-C17-Dibenzo-p- <0.42 <0.15 <0.15 <0.11 <0.19 <0.18 <0.17 <0.077
dioxin
1,2,3,4,6,7,8,9-C18- <0.31 <0.14 <0.14 <0.11 <0.18 <0.17 <0.16 <0.078
Dibenzofuran
1,2,3,4,6,7,8,9-C18-Dibenzo- <0.35 <0.16 <0.16 <0.12 <0.21 <0.19 <0.22 0.33
p-dioxin
4.0 Discussion
The levels of metals' found in each of the areas samples were generally low to moderate.
These concentrations are not considered hazardous as there is insufficient mass to allow for
significant exposure. There are no standards for acceptable levels of metals in settled dusts in
office environments. However the amount of materials identified are small and if they were
completely suspended in the office atmosphere the resulting concentrations would not exceed the
OSHA Permissible Exposure Limits.
The levels of dioxin and dioxin like compounds in the areas sampled were generally non
detected. Two detectable concentrations are considered low and would be incapable of
generating airborne concentrations in excess of the U.S. EPA screening Ievel.
Page -5-
NYC-WTC 000095881
OCR can misread numbers and units. Confirm readings against the page image before using them.