Air monitoring report cover sheet, 345 South End Ave, 2001

Machine-extracted title · confidence 90%

Cover page for an air monitoring and bulk sampling report for Building #200 at 375 South End Avenue.

NYC-WTC_000095478–000095630

Folder label: “345 SOUTH END AVENUE Block: 16 Lot: 100

Page image
Scanned page image, NYC-WTC_000095582
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

104 East 25th Street New York. New York 10010 www.atc•ernriro.com

TC A S 8 O C I A T E S r N C

October 8, 2001 212.353.8280 Fax 212.353.8306

ALC Environmental 1:.5 W. 30th Street New York, NY 10001 Attn: Mr. Joshua Sarett Re: Report of TEM Analysis

Dear Mr. Sarett: trarsmissior_ electron microscopy (TEM) Following are the results of Group Ne. 5633. analysis of air samples from our

Client: Gateway Plaza Mngt. Corp. Plaza - 355 South E:id Ave. Project Name: Building 200 at Gateway Location: Various Sites Samples received: 10/08/01 document the data transmitted today These results will confirm and performed in strict conformance with the to you. The analyses were (CFR October 30, :987) for methodology of the AHERA Final Rule indicated on the attached Summary clearance of abatement sites. As structures were detected i:: any of the Results sheet, no asbestos site. five samples submitted from the a '- unction of air volume Results reported as Struct/cc are not verifiable by this collected in the field and are, as such, reproduced only '-n its entirety and laboratory. This report may be laboratory. If the post - not without prior permission of this response action may be abatement inside samples pass, the analyses were supervised by considered to have been completed. TheElectron Microscopy. of Dr. Michael A. Gorycki, Director our TEM lab has received full We are pleased to note that currently required for recognized arcrediation from NVLAP, as is projects, and also approval analysis of TEM air samples for AHERA These analyses were performed under the NY State DOH FLAP program. by ATC d/b/a ATC Associates Inc. questions relating to these Please contact me regarding any materials.

Very truly yours,

/iJQ Michael A. Gorycki, Pft. D. Director of Electron Microscopy

NYC-WTC 000095582

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000095582Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000121364 · Box DEP Box 48

Chain of custody for air samples collected at 345 South End Avenue buildings in late January and early February 2002.

Similar indexed content

Compare copies and versions →