NYC-WTC_000093400
A license agreement document regarding exterior cleaning services for the property at 65 Liberty Street.
12 shared non-person entities · similarity 0.985
machine-extracted · confidence unavailable · Check page ↗Invoice detailing billing for bulk and air sample analysis results including PLM, PCM, and TEM testing at 44 Wall Street.
NYC-WTC_000094912–000095002Folder label: “44 WALL STREET Block: 43 Lot: 1”

OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Hillmann Environmental Group, LLC
SECTION 1— EXECUTIVE SUMMARY
1.1 General
On four dates, Ms. Jennifer L. Collins, IH of Hillmann Environmental Group, LLC (Hillmann), conducted an Indoor Air Quality Investigation at 44 Wall Street, New York, New York. The investigation is designed to identify indoor air quality contaminants as well as any residual effects from the recent World Trade Center Collapse.
Hillmann's site investigator performed a visual inspection for conditions that could negatively impact indoor air quality. The investigator measured temperature, relative humidity, carbon dioxide, carbon monoxide, volatile organic compounds, hydrogen sulfide, oxygen, combustible gasses, and collected airborne asbestos fiber and bulk asbestos samples.
1.2 Findings
On the days of the investigation, inside the building, temperature and relative humidity readings were collected. Temperatures ranged from 69°F to 78°F and relative humidities ranged from 39% to 69%. The American Society of Heating, Refrigeration and Air-conditioning Engineers (ASHRAE) recommends that temperatures stay within the range of 66°F to 76°F and that relative humidities stay within the range of 30% to 60%. Temperatures and relative humidities were above the recommended range in some instances.
• Carbon dioxide levels ranged from 521 ppm to 1044 ppm. ASHRAE recommends carbon dioxide levels remain below an outdoor reading plus 700 ppm. The outdoor readings ranged from 521 ppm to 535 ppm, therefore the recommended limits were 1221 ppm to 1235 ppm. Carbon dioxide levels did not exceed the recommended range.
• Observed carbon monoxide levels ranged from below the limit of detection of 1 ppm to 2 ppm. These levels are well below the recommended limits, including the Environmental Protection Agency (EPA) National Ambient Air Quality Standard (NAAQS) of 9 ppm.
Levels of volatile organic compounds ranged from below the limit of detection of 0.1 ppm to 7.4 ppm. Hillmann recommends that levels of volatile organic compounds remain below three times the background outdoor reading. Since the outdoor readings taken during the investigations were below the limit of detection of 0.1 ppm, the recommended limit would be 0.3 ppm. The only elevated reading occurred in the penthouse area during the time roof repair was occurring. This elevated level had returned to below the recommended limit on a follow-up visit.
• Hydrogen sulfide is a colorless gas with a strong odor that can often be present during or after a fire. The Occupational Safety and Health Administration (OSHA) Permissible Exposure Limit (PEL) is 10 ppm. In the subject space, levels were found to be below the limit of detection of 1 ppm. These levels were below recommended limits.
• The normal level of oxygen in air, at sea level, is 20.9%. If oxygen levels in a space are at or below 19.5%, the space is considered oxygen deficient (by OSHA 29 CFR Part1910.94, 30 CFR Part 11 and ANSI Standard Z88.5-1973) and is unable to safely support human occupancy. The oxygen levels ranged from 20.7% to 21.2%, and were within normal levels.
Cushman & Wakefield/44 Wall Street, New York, NY/Project Number N3-7476 Page 1
NYC-WTC 000094933
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
No available related records indexed in this group.
NYC-WTC_000093400
A license agreement document regarding exterior cleaning services for the property at 65 Liberty Street.
12 shared non-person entities · similarity 0.985
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000146129
Correspondence from NYC Corporation Counsel providing comments on excerpts of a draft EPA evaluation report regarding the WTC response.
21 shared non-person entities · 1 shared topics · similarity 0.983
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000120388
Laboratory report detailing air sampling and dust analysis conducted at 88 Pine Street from September 13 to 21, 2001.
25 shared non-person entities · 1 shared topics · similarity 0.982
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000120940
Document tracking environmental samples collected from Building #100 at 345 South End Avenue on October 22, 2001.
12 shared non-person entities · 1 shared topics · similarity 0.980
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000099818
Billing record for asphalt and gravel roof cleanup services performed at 55 Nassau Street in November 2002.
6 shared non-person entities · similarity 0.980
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000125801
Cover sheet for a fax transmission from DEP regarding the 105 Duane Street site file.
16 shared non-person entities · 1 shared topics · similarity 0.979
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000111963
Billing statement from Fiber Control Inc. for work performed at the 12 Vesey Street job site.
5 shared non-person entities · 1 shared topics · similarity 0.979
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000123194
Invoice for roof asbestos abatement work completed at 198 Broadway covering nearly 25,000 square feet.
7 shared non-person entities · similarity 0.978
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000115228
Invoice from Benjamin Kurzban & Son to the DEP for work completed at 213 Pearl Street on September 24, 2002.
5 shared non-person entities · similarity 0.978
machine-extracted · confidence unavailable · Check page ↗13 shared non-person entities · 1 shared topics · similarity 0.978
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000120991
Record documenting the transfer and custody of air samples from Building #100 at 345 South End Avenue collected on October 22, 2001.
11 shared non-person entities · 1 shared topics · similarity 0.978
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000100474
Billing statement from a contractor detailing charges for environmental cleanup and facade work.
6 shared non-person entities · 1 shared topics · similarity 0.978
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
Page similarity is temporarily unavailable or this page has no indexed vector.
Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000145027
Notice from NYC Law Department instructing staff to preserve World Trade Center documents for potential legal actions.
Cited alongside this record in an Ask answer
NYC-WTC_000150209
Laboratory report listing PCM and TEM asbestos air sampling results collected on September 26, 2001.
Cited alongside this record in an Ask answer
NYC-WTC_000150233
Cover page for a laboratory report regarding landfill operations, dated October 2001.
Cited alongside this record in an Ask answer
Review draft of an environmental health and safety plan for debris operations at Staten Island Landfill.
Cited alongside this record in an Ask answer
Cited alongside this record in an Ask answer