NYC 9/11 Public Portal Document
JLC ENVIRONMENTAL CONSULTANTS, INC.
200 Park Avenue South, Suite 1001, New York, New York 10003
Phone: (212) 420-8119 Fax: (212) 420-6092
Project No.: 01-2089003
Rose Associates Inc. ELAP Lab Code: 11029 Anatyte: FIBERS
200 Madison Ave. 5th Floor NIOSH and AIHA Lab Code: 100273 Date Received: 10/19/2001
New York, NY 10016 NVLAP Lab Code: 101953 Date Analyzed: 10/19/2001
Batch #: 0110A792
SUMMARY OF ANALYTICAL RESULTS
Site: 21 West Street, New York, NY
L
SAMPLE #
COLLECTED DESCRIPTION I LOCATION TIME(min) VOLUME(l) ' FIB/FIELD RESULTS(f/cc)
LAB #
019. Ambient! 6th Floor/ Apt. 6M At the North Section 120 1846 4/100 0.001<LOD
ot me Apt.
A 8060
020 Ambient/ 6th Floor/ Hallway Between Apt. 6E and 120 1846 16/100 0.004
18-October 6F
A 8061
021 Ambient/ 3rd Floor/ Apt. 3F/ At the North Section 120 1846 2/100 <0.001<LOD
18-October of the Living Room
A 8062
022 Ambient/ 3rd Floor/ Hallway/ At the Entrance to 120 1846 3/100 <0.001<LOD
18-October the Laundry Room
A 8063
023 Ambient/ Lobby/ At the Entrance to the Mail Room 120 1846 3/100 <0.001<LOD
18-October
A 8064
024 Ambient/ Lobby/ At the Entrance to the Clock 120 1846 14/100 0.004
18-October Room
A 8065
Sample Analysis by: <LOD = Less than limit of detection which Is 5.5 Fibers/ 100 Fields
VOIDI = H.C.P. ( High Concentration of Particles)
Positive Phase Contrast Microscopy (PCM)
VOID2 = Overloaded
Method of Sample Preparation and Analysis:
All samples analyzed In accordance with the NIOSH 7400 Method using "A" Counting Rules. Issue 2, August 1994
Instrumentation: ~~ ,. ~(\ a
U am ac Iwa a
Olympus PCM Model SH-2 with Walton-Beckett Graticule (100um field diameter).
Laboratory Director
Report Date: October 23, 2001
JLC Is responsible for only the fiber counts within the limitations of the method described as NIOSH 7400. Among other limitations, this
method gives only an Index of airborne fibers and provides only an estimate of asbestos concentration. Any and all claims arising out of
JLC's analysis of these samples are limited In recovery to the cost of analyzing samples. JLC accepts no other liability and the client agrees
to seek no costs beyond the above.
Page 4 of 5
NYC-WTC 000094645
OCR can misread numbers and units. Confirm readings against the page image before using them.