Preservation Brief 7: The Preservation of Historic Glazed Architectural Terra-Cotta Page 4 of 14

material.

Deterioration creates a "domino"like breakdown of the whole system: glazed units, mortar, metal anchors, and masonry backfill. In no other masonry system is material failure potentially so complicated.

Poor original design: The root of deterioration in glazed architectural terra-cotta systems often lies in a misapplication of the material. Historically, glazed architectural terra-cotta was viewed as a highly waterproof system needing neither flashing, weep holes nor drips. This supposition, however, has proved to be untrue, as serious water- related failure was evident early in the life of many glazed architectural terra-cotta clad or detailed buildings.

Common Deterioration Problems No one case of deterioration in glazed architectural terra-cotta is ever identical to another owing to the infinite number of variations with the material: original manufacture, original installation inconsistencies, number of component parts, ongoing repairs or the various types and sources of deterioration. However, certain general statements may be made on the nature of glazed architectural terra-cotta deterioration.

Material failure can most commonly be attributed to water-related problems. However, less frequent though no less severe causes may include: faulty original craftsmanship, which is often cited but hard to determine; stress-related deterioration; damage caused by later alterations and additions; or inappropriate repairs.

Water-related deterioration: As with most building conservation and rehabilitation problems, water is a principal source of deterioration in glazed architectural terra-cotta. Terra-cotta systems are highly susceptible to such complex water-related deterioration problems as glaze crazing, glaze spalling and material loss, missing masonry units and deteriorated metal anchoring, among others.

Crazing, or the formation of small random cracks in the glaze, is a common form of water-related deterioration in glazed architectural terra-cotta. When the new terra- ~ cotta unit first comes from the kiln after firing, "" it has shrunken (dried) to its smallest possible size. With the passage of time, however, it -' expands as it absorbs moisture from the air, a . process which may continue for many years. " The glaze then goes into tension because it Water and air-borne moisture entering the glazed has a lesser capacity for expansion than the architectural terra-cotta causes expansion of the porous tile body; it no longer "fits" the porous clay body, increasing Its volume. This upsets expanding unit onto which it was originally the "fit" of the glaze and makes its surface shatter, which is commonly called "crazing." Photo: NPS flies. fired. If the strength of the glaze is exceeded, it will crack (craze). Crazing is a process not unlike the random hairline cracking on the surface of an old oil painting. Both may occur as a normal process in the aging of the material. Unless the cracks visibly extend into the porous tile body beneath the glaze, crazing should not be regarded as highly serious material failure. It does, however, tend to increase the water absorption capability of the glazed architectural terra-cotta unit.

Spalling, the partial loss of the masonry material itself, is, like crazing, caused by water and is usually a result not only of airborne water but more commonly of water trapped within the masonry system itself. Trapped water is often caused by poor water detailing

http://www2.cr.nps.gov/tps/briefs/briefD7.htm 10/3/2001

NYC-WTC 000093841

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000093841Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →