ICP-MS Method 200.8 results, Jan 8, 2002

Machine-extracted title · confidence 100%

Lab report detailing ICP-MS analysis of water samples for metals using Method 200.8 on January 8, 2002.

NYC-WTC_000086257–000086384

Folder label: “NEWQ 01/08/2002 31404 - 31662

Page image
Scanned page image, NYC-WTC_000086265
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Method 200.8 - Summary Report Sample ID: ICV STD1 30 PPB Sample Date/Time: Tuesday, January 08, 2002 12:18:37 Sample Type: Sample Sample Description: Number of Replicates: 3 Batch ID: Method File: d:\elandata\Method\NEWQ200.8.mth Dataset File: d:\elandata\Dataset\daily performanceMCV STD1 30 PPB.1863 Sample Prep Volume (mL): Initial Sample Quantity (mg): Aliquot Volume (mL): Diluted To Volume (mL):

Concentration Results Analyte Mass Meas. Intens. Mean Meas. Intens. RSD Net Intens. Mean Cone. Mean Cone. RSD Sample Unit r Be 9 15348.435 1.689 0.023 29.38316 2.91 ug/L I: Se-I 45 665772.432 4.105 665772.432 ug/L I Cr 52 359227.174 7.192 0.527 29.69382 11.01 ug/L I Cr 53 43359.012 3.657 0.064 31.53659 1.03 ug/L I Mn 55 572631.588 4.564 0.861 30.37592 7.93 ug/L I Ni 60 93303.670 3.476 0.140 31.40786 1.86 ug/L I Cu 63 216620.691 1.594 0.320 30.67172 3.79 ug/L L Cu 65 104674.534 5.001 0.155 29.61040 9.30 ug/L r Zn 66 68890.947 3.559 0.579 29.76352 3.71 ug/L 1 Zn 67 11572.160 5.854 0.097 27.71751 6.81 ug/L I Zn 68 49060.591 2.956 0.412 29.24382 3.08 ug/L I: Ge 72 117924.474 1.070 117924.474 ug/L 1 As 75 69360.405 1.158 0.584 30.89447 0.42 ug/L I Se 77 6339.274 2.693 0.053 32.23766 2.51 ug/L L Se 82 8355.591 3.214 0.068 32.56087 3.07 ug/L r Ag 107 351310.552 2.011 0.251 29.47825 1.71 ug/L I: In 115 1396338.086 1.599 1396338.086 ug/L I Sb 121 263686.631 2.752 0.189 32.34071 1.63 ug/L L Sb 123 208213.302 2.437 0.149 33.27002 3.69 ug/L r Ba 135 81324.282 0.605 0.043 29.71808 3.04 ug/L I Ba 137 142449.831 0.707 0.075 29.72619 3.29 ug/L I: Ho 165 1898558.664 2.621 1898558.664 ug/L I Tl 205 932342.111 3.780 0.491 31.48687 6.08 ug/L L Pb 208 1253806.781 2.106 0.658 27.18303 2.28 ug/L

Sample ID: ICV STD1 30 PPB Report Date/Time: Tuesday, January 08, 2002 12:20:09 Page 1

NYC-WTC_000086265

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000086265Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

ICP-MS summary report, Jan 4 2002 · Box DEP Box 66

NYC-WTC_000085362

Method 200.8 laboratory summary report listing elemental concentrations including Beryllium, Scandium, Chromium, Manganese, Nickel, and Copper.

1 shared topics · Same agency, volume and box · similarity 0.999

machine-extracted · confidence unavailable · Check page ↗
ICP-MS summary report, Jan 3 2002 · Box DEP Box 66

NYC-WTC_000085227

Method 200.8 laboratory summary report listing elemental concentrations including Beryllium, Scandium, Chromium, Manganese, Nickel, and Copper.

1 shared topics · Same agency, volume and box · similarity 0.999

machine-extracted · confidence unavailable · Check page ↗
ICP-MS summary report, Jan 10 2002 · Box DEP Box 66

NYC-WTC_000085591

Method 200.8 laboratory summary report listing elemental concentrations including Beryllium, Scandium, Chromium, Manganese, Nickel, and Copper.

1 shared topics · Same agency, volume and box · similarity 0.998

machine-extracted · confidence unavailable · Check page ↗

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →