NYC-WTC_000086257
Lab report detailing ICP-MS analysis of water samples for metals using Method 200.8 on January 8, 2002.
1 shared topics · Same agency, volume and box · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗Lab report detailing ICP-MS analysis of water samples for metals using Method 200.8 on January 7, 2002.
NYC-WTC_000086174–000086255Folder label: “NEWQ 01/07/2002 31249 - 31403”

OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Method 200.8 - Summary Report Sample ID: ICV STD1 30 PPB Sample Date/Time: Monday, January 07, 2002 14:19:35 Sample Type: Sample Sample Description: Number of Replicates: 3 Batch ID: Method File: d:\elandata\Method\NEWQ200.8. mth Dataset File: d:\elandata\Dataset\daily performanceMCV STD1 30 PPB.1803 Sample Prep Volume (ml): Initial Sample Quantity (mg): Aliquot Volume (mb): Diluted To Volume (mL):
Concentration Results Analyte Mass Meas. Intens. Mean Meas. Intens. RSD Net Intens. Mean Cone. Mean Cone. RSD Sample Unit r Be 9 14678.994 2.699 0.022 29.68977 2.14 ug/L I: Se-I 45 671258.794 0.669 671258.794 ug/L I Cr 52 373441.672 1.008 0.540 29.87429 1.42 ug/L I Cr 53 42585.613 1.260 0.062 28.75006 1.22 ug/L I Mn 55 569915.337 3.619 0.848 29.42116 4.27 ug/L I Ni 60 88244.163 3.768 0.131 28.40165 3.46 ug/L I Cu 63 212932.871 2.784 0.316 30.44549 3.14 ug/L L Cu 65 104609.902 3.291 0.155 30.75476 2.94 ug/L r Zn 66 70034.211 2.577 0.578 30.66462 3.84 ug/L I Zn 67 12638.241 2.008 0.104 31.24427 2.25 ug/L I Zn 68 51729.707 3.160 0.427 30.55498 4.34 ug/L I: Ge 72 119829.853 1.227 119829.853 ug/L I As 75 70221.513 2.033 0.582 29.56667 2.89 ug/L I Se 77 6414.994 1.149 0.052 29.14385 1.98 ug/L L Se 82 8329.899 1.717 0.067 29.26096 3.02 ug/L r Ag 107 353251.848 4.280 0.256 30.64972 5.82 ug/L i: In 115 1378803.752 2.589 1378803.752 ug/L I Sb 121 263658.739 0.579 0.191 30.00112 3.06 ug/L L Sb 123 201008.227 0.546 0.146 29.34300 2.58 ug/L r Ba 135 79583.406 2.303 0.043 30.00877 2.52 ug/L I Ba 137 139906.066 2.217 0.076 30.54474 2.77 ug/L I: Ho 165 1836848.837 0.693 1836848.837 ug/L I Tl 205 900058.275 1.960 0.490 30.68824 1.32 ug/L L Pb 208 1286273.159 2.323 0.697 32.19630 2.14 ug/L
Sample ID: ICV STD1 30 PPB Report Date/Time: Monday, January 07, 2002 14:21:07 Page 1
NYC-WTC_000086182
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000086257
Lab report detailing ICP-MS analysis of water samples for metals using Method 200.8 on January 8, 2002.
1 shared topics · Same agency, volume and box · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000085362
Method 200.8 laboratory summary report listing elemental concentrations including Beryllium, Scandium, Chromium, Manganese, Nickel, and Copper.
1 shared topics · Same agency, volume and box · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000085227
Method 200.8 laboratory summary report listing elemental concentrations including Beryllium, Scandium, Chromium, Manganese, Nickel, and Copper.
1 shared topics · Same agency, volume and box · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000085591
Method 200.8 laboratory summary report listing elemental concentrations including Beryllium, Scandium, Chromium, Manganese, Nickel, and Copper.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000086120
Lab report detailing ICP-MS analysis of water samples for beryllium, scandium, chromium, manganese, nickel, and copper on January 4, 2002.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000067263
Summary report of Method 200.8 analysis results for multiple analytes including beryllium, chromium, and manganese from December 20, 2001.
1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000067008
Summary report of Method 200.8 analysis results for multiple analytes including beryllium, chromium, and manganese from December 18, 2001.
1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000067061
Summary report of Method 200.8 analysis results for multiple analytes including beryllium, chromium, and nickel from December 18, 2001.
1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000067178
Summary report of Method 200.8 analysis results for multiple analytes including beryllium, chromium, and manganese from December 19, 2001.
1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000066601
Summary report of Method 200.8 analysis results for multiple analytes including beryllium and chromium from December 13, 2001.
1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000066921
Summary report of Method 200.8 analysis results for multiple analytes including beryllium, chromium, and nickel from December 12, 2001.
1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000066458
Summary report of Method 200.8 analysis results for multiple analytes including selenium and germanium from December 13, 2001.
1 shared topics · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000086257
Lab report detailing ICP-MS analysis of water samples for metals using Method 200.8 on January 8, 2002.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000085227
Method 200.8 laboratory summary report listing elemental concentrations including Beryllium, Scandium, Chromium, Manganese, Nickel, and Copper.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000085362
Method 200.8 laboratory summary report listing elemental concentrations including Beryllium, Scandium, Chromium, Manganese, Nickel, and Copper.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000086120
Lab report detailing ICP-MS analysis of water samples for beryllium, scandium, chromium, manganese, nickel, and copper on January 4, 2002.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000076077
Summary of water sample results for metals analysis using Method 200.8 conducted on January 24, 2002.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000085726
Method 200.8 laboratory summary report listing elemental concentrations including Beryllium, Selenium, Chromium, Manganese, and Nickel.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000086173
A single-page Department of Environmental Protection document covering World Trade Center site batches from January 7, 2002.
Filed in the same folder
NYC-WTC_000086257
Lab report detailing ICP-MS analysis of water samples for metals using Method 200.8 on January 8, 2002.
Similar indexed content
NYC-WTC_000085362
Method 200.8 laboratory summary report listing elemental concentrations including Beryllium, Scandium, Chromium, Manganese, Nickel, and Copper.
Similar indexed content
NYC-WTC_000085227
Method 200.8 laboratory summary report listing elemental concentrations including Beryllium, Scandium, Chromium, Manganese, Nickel, and Copper.
Similar indexed content
NYC-WTC_000067263
Summary report of Method 200.8 analysis results for multiple analytes including beryllium, chromium, and manganese from December 20, 2001.
Similar indexed content