NYC Law Department release Independent mirror · updated as the City releases more · v1.5.1 ☕ Buy me a coffee
← Document results/DEP Box 66/NEWE 1/11/2002 AD 31456 - AE00110 Batches 16390 16391 16402 copies made
Document / 60 pages
Method 200.8 ICP-MS lab results, NEWE samples, Jan 11, 2002
Machine-extracted title · confidence 85%
ICP-MS analysis of water samples using Method 200.8 with elemental measurements (Be, Sc, Mn, In, Sb, Ho) and quality control replicates performed on January 11, 2002.
Method 200.8 - Summary Report
Sample ID: AD31676
Sample Date/Time: Friday, January 11,2002 14:53:52
Sample Type: Sample
Sample Description:
Number of Replicates: 3
Batch ID:
Method File: d:\elandata\Method\NEWE200.8.mth
Dataset File: d:\elandata\Dataset\daily performance\AD31676.2057
Sample Prep Volume (mL):
Initial Sample Quantity (mg):
Aliquot Volume (mL):
Diluted To Volume (mL):
Concentration Results
Analyte Mass Meas. Intens. Mean Meas. Intens. RSD Net Intens. Mean Cone. Mean Cone. RSD Sample Unit
r Be 9 13.333 8.660 0.000 0.00619 50.75 ug/L
|> Sc-1 45 587216.298 2.644 587216.298 ug/L
L Mn 55 2190415.690 1.797 3.730 129.30314 0.98 ug/L
r> In 115 1237395.628 1.616 1237395.628 ug/L
I Sb 121 822.045 5.772 0.001 0.09891 4.79 ug/L
L Sb 123 612.840 2.093 0.000 0.09608 0.56 ug/L
r> Ho 165 1682055.527 2.264 1682055.527 ug/L
L Tl 205 520.354 8.579 0.000 0.01218 10.44 ug/L
QC Calculated Values
Analyte Mass QC Std % Recovery I nt Std % Recovery Spike % Recovery Dilution % Diff Dup. Rei. % Diff
r Be g
|> Sc-1 45 92.483
L Mn 55
r> In 115 93.829
I Sb 121
L Sb 123
r> Ho 165 93.654
L Tl 205
Calibration
Analyte MassCurve Type Correlation Coefficient
r Be 9Linear Thru Zero 0.999992
|> Sc-1 45Linear Thru Zero
L Mn 55Linear Thru Zero 0.999983
r> In 115Linear Thru Zero
I Sb 121 Linear Thru Zero 0.999998
L Sb 123Linear Thru Zero 1.000000
r> Ho 165Linear Thru Zero
L Tl 205Linear Thru Zero 0.999977