Method 200.8 ICP-MS lab results, NEWE samples, Jan 11, 2002
Machine-extracted title · confidence 85%
ICP-MS analysis of water samples using Method 200.8 with elemental measurements (Be, Sc, Mn, In, Sb, Ho) and quality control replicates performed on January 11, 2002.
Method 200.8 - Summary Report
Sample ID: AD31672
Sample Date/Time: Friday, January 11, 2002 14:36:54
Sample Type: Sample
Sample Description:
Number of Replicates: 3
Batch ID:
Method File: d:\elandata\Method\NEWE200.8.mth
Dataset File: d:\elandata\Dataset\daily performance\AD31672.2050
Sample Prep Volume (mL):
Initial Sample Quantity (mg):
Aliquot Volume (mL):
Diluted To Volume (mL):
Concentration Results
Analyte Mass Meas. Intens. Mean Meas. Intens. RSD Net Intens. Mean Cone. Mean Cone. RSD Sample Unit
r Be 9 11.667 27.553 0.000 0.00214 353.40 ug/L
|> Sc-1 45 601728.559 3.770 601728.559 ug/L
L Mn 55 1973139.184 1.768 3.280 113.71453 2.67 ug/L
r> In 115 1263095.415 1.098 1263095.415 ug/L
I Sb 121 598.692 6.607 0.000 0.06941 7.38 ug/L
L Sb 123 440.156 6.210 0.000 0.06642 7.06 ug/L
r> Ho 165 1764627.242 2.420 1764627.242 ug/L
L Tl 205 270.673 2.621 0.000 0.00212 1.01 ug/L
QC Calculated Values
Analyte Mass QC Std % Recovery I nt Std % Recovery Spike % Recovery Dilution % Diff Dup. Rei. % Diff
r Be 9
|> Sc-1 45 94.769
L Mn 55
r> In 115 95.778
I Sb 121
L Sb 123
r> Ho 165 98.251
L Tl 205
Calibration
Analyte MassCurve Type Correlation Coefficient
r Be 9Linear Thru Zero 0.999992
|> Sc-1 45Linear Thru Zero
L Mn 55Linear Thru Zero 0.999983
r> In 11SLinear Thru Zero
I Sb 121 Linear Thru Zero 0.999998
L Sb 123Linear Thru Zero 1.000000
r> Ho 165Linear Thru Zero
L Tl 205Linear Thru Zero 0.999977