Quantitation Report (Not Reviewed)
Data File C:\HPCHEM\l\DATA\02apr03\0403C10.D Vial: 2
Acq On 3 Apr 2002 9:34 am Operator: 201-wb
Sample cal 10 Inst : GC/MS Ins
Mise Multiplr: 1.00
MS Integration Params: RTEINT.P
Quant Time: Apr 3 10:12 2002 Quant Results File: HP031802.RES
Quant Method : C:\HPCHEM\1\METHODS\HP031802.M (RTE Integrator)
Title : VOCs BY EPA METHOD 524
Last Update : Thu Mar 28 15:03:13 2002
Response via : Initial Calibration
DataAcq Meth : HP031802
Compound R.T. Qlon Response Cone Unit Qvalue
49) 0-XYLENE 23.04 91 919042 10.76 ug/L 96
50) STYRENE 23.09 104 563293 9.95 ug/L 95
51) 1,1,2,2-TETRACHLOROETHANE 24.11 83 129906 8.32 ug/L 98
53) BROMOFORM 23.96 173 96983 10.99 ug/L 99
54) ISOPROPYLBENZ ENE 23.75 105 1013806 11.50 ug/L 99
55) 1,2,3-TRICHLOROPROPANE 24.45 110 46919 9.93 ug/L 94
56) N-PROPYLBENZENE 24.64 91 1293854 11.29 ug/L 97
5 7) BROMOBENZENE 24.88 156 243479 10.50 ug/L 97
58) 1,3,5-TRIMETHYLBENZENE 24.94 105 910938 11.65 ug/L 95
59) 2-CHLOROTOLUENE 25.11 91 879140 11.15 ug/L 97
60) 4-CHLOROTOLUENE 25.18 91 790881 11.66 ug/L 97
61) TERT-BUTYLBENZENE 25.74 119 809713 11.34 ug/L 92
62) 1,2,4-TRIMETHYLBENZENE 25.83 105 935806 11.44 ug/L 94
63) SEC-BUTYLBENZENE 26.20 105 1100958 11.23 ug/L 97
64) P-ISOPROPYLTOLUENE 26.46 119 860830 11.25 ug/L 96
65) 1,3-DICHLOROBENZENE 26.82 146 463069 10.47 ug/L 97
66) 1,4-DICHLOROBENZENE 27.04 146 462574 10.11 ug/L 99
67) N-BUTYLBENZENE 27.34 91 878996 11.30 ug/L 99
68) 1,2-DICHLOROBENZENE 27.89 146 379085 10.02 ug/L 97
69) 1,2-DIBROMO-3-CHLOROPROPAN 29.68 157 17821 7.64 ug/L 94
70) 1,2,4-TRICHLOROBENZENE 31.97 180 247419 10.35 ug/L 99
71) HEXACHLOROBUTADIENE 32.28 225 159712 12.93 ug/L 96
72) NAPHTHALENE 32.81 128 254434 8.67 ug/L 99
73) 1,2,3-TRICHLOROBENZENE 33.52 180 191898 10.27 ug/L 97
74) NITROBENZENE 29.90 77 95755 161.47 ug/L 93
(#) = qualifier out of range (m) = manual integration
0403C10.D HP031802.M Wed Apr 03 10:13:22 2002 Page 2