Chlordane method validation data, Nov 2001

Machine-extracted title · confidence 100%

Method validation report for chlorinated pesticides listing compound responses, averages, and percent relative standard deviations.

NYC-WTC_000081414–000081415

Folder label: “508 Xtract 10/4/01 Anal 10/31/01

Page image
Scanned page image, NYC-WTC_000081414
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document Quantitation Report (QT Reviewed) Signal #1 C:\HPCHEM\l\DATA\508F\011030B\2CHLC2.D\ECDlA.CHVial: 58 ’ Signal #2 C:\HPCHEM\1\DATA\5O8F\O11O3OB\2CHLC2.D\ECD2B.CH Acq On 1 Nov 2001 10:46 am Operator; Nefliu Sample chlordane ccv2 Inst : 104 Mise : Multiplr: 1.00 IntFile Signal #1: events.e IntFile Signal #2: events2.e Quant Time: Nov 2 10:31 2001 Quant Results File: 011029C.RES

Quant Method : C:\HPCHEM\1\METHODS\011029C.M (Chemstation Integrator) Title : DUAL 508 CHLORINATED PESTICIDES CHLORDANE 6/3/99 Last Update : Sun Oct 21 15:44:45 2001 Response via : Initial Calibration DataAcq Meth : 508F2.M Volume Inj. Signal #1 Phase Signal #2 Phase: Signal #1 Info Signal #2 Info ; Compound RT#1 RT#2 Resp#l Resp#2 ug/L ug/L

System Monitoring Compounds 4) S 2,4-DDD SURROGAT 36.98f 34.Ilf 918716 1091827 0.240m 0.220m Spilced TVnount 0.2 00 Recovery = 120.00% 110.00% Target Compounds 1) CHLORDANE PEAK 1 31.99f 31.48 325035 1608221 1.714m 1.682m 2) CHLORDANE PEAK 2 33.15f 31.81 1506173 2223450 1.789m 1.682m 3) CHLORDANE PEAK 3 34.10f 35.69 1323434 523930 1.757m 1.700m

(f)=RT Delta > 1/2 Window (#)=Amounts differ by > 25% (m)=manual int. 2CHLC2.D 011029C.M Fri Nov 02 10:32:06 2001 Page 1

NYC-WTC_000081414

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000081414Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →