Method 200.8 Water Analysis Summary Report, Mar 21, 2002

Machine-extracted title · confidence 95%

Summary of water sample results for metals analysis using Method 200.8 conducted on March 21, 2002.

NYC-WTC_000077433–000077558

Folder label: “9 March 21, 2002 NEWN AE04030 - AE04512

Page image
Scanned page image, NYC-WTC_000077464
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

I Cr 53 97.961 I Mn 55 98.182 Ni 60 92.038 Cu 63 92.275 L Cu 65 90.229 r Zn 66 100.470 I Zn 67 98.339 I Zn 68 97.729 i> Ge 72 88.555 I As 75 102.090 1 Se 77 107.309 L Se 82 105.231 Y 89 r Ag 107 83.922 I Cd 111 99.143 Cd 114 100.218 |> In 115 86.560 Sb 121 103.677 L Sb 123 102.873 r Ba 135 95.962 Ba 137 94.157 i> Tb 159 i Ho 165 1 Tl 205 95.696 L Pb 208 89.611 Calibration Analyte MassCurve Type Correlation Coefficient r Be 9Linear Thru Zero 0.999998 i> Sc-1 45Linear Thru Zero I Cr 52Linear Thru Zero 0.999947 I Cr 53Llnear Thru Zero 0.999988 1 Mn 55Linear Thru Zero 0.999929 Ni 60Unear Thru Zero 0.999992 1 Cu 63Linear Thru Zero 0.999870 L Cu 65Linear Thru Zero 0.999973 r Zn 66Linear Thru Zero 0.999997 1 Zn 67Linear Thru Zero 0.999992 I Zn 68Linear Thru Zero 0.999998 i> Ge 72Linear Thru Zero As 75Linear Thru Zero 0.999965 I Se 77Linear Thru Zero 0.999953 L Se 82Linear Thru Zero 0.999996 Y 89Linear Thru Zero Ag 107Linear Thru Zero 0.999998 Cd 111 Linear Thru Zero 0.999953 Cd 114Linear Thru Zero 0.999983 > In 115Linear Thru Zero Sb 121 Linear Thru Zero 0.999991 Sb 123Linear Thru Zero 0.999995

Sample ID: AE04030 Report Date/Time: Thursday, March 21, 2002 09:48:52 Page 2

NYC-WTC_000077464

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000077464Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →