NYC-WTC_000077357
Summary of water sample results for metals analysis using Method 200.8 conducted on March 19, 2002.
1 shared topics · Same agency, volume and box · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗Summary of water sample results for metals analysis using Method 200.8 conducted on March 19, 2002.
NYC-WTC_000077278–000077355Folder label: “7 March 19, 2002 NEWN AE03388 - AE03798”

OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
WESTCHESTER COUNTY DEPT OF LABS AND RESEARCH Method 200.8 - Summary Report Sample ID: AE03504 Sample Date/Time: Tuesday, March 19, 2002 11:04:22 Sample Type: Sample Sample Description: Number of Replicates: 3 Batch ID: Method File: d:\elandata\Method\NYC.mth Dataset File: d:\elandata\dataset\new york city\AE03504.026 Aliquot Volume (mL): Diluted To Volume (mL):
Concentration Results Analyte Mass Meas. Intens. Mean Meas. Intens. RSD Net Intens. Mean Cone. Mean Cone. RSD Sample Unit r Se-I Be 9 11.333 20.377 -0.000 -0.00283 136.08 ug/L i> 45 649547.650 0.963 649547.650 ug/L I Cr 52 11384.906 1.225 0.004 0.22126 7.94 ug/L 1 Cr 53 1245.098 1.501 0.001 0.50084 2.45 ug/L Mn 55 362586.701 1.525 0.557 19.01763 2.48 ug/L I Ni 60 1157.085 2.492 0.001 0.29581 2.61 ug/L I Cu 63 10087.696 1.754 0.013 1.15746 2.65 ug/L L Cu 65 5005.763 4.519 0.006 1.20083 6.51 ug/L r Zn 66 3018.865 4.086 0.011 0.60753 9.36 ug/L 1 Zn 67 720.036 4.507 0.004 1.12962 5.39 ug/L 1 Zn 68 2961.846 2.644 0.014 1.02520 4.63 ug/L i> Ge 72 119580.608 1.289 119580.608 ug/L I As 75 569.014 10.254 0.005 0.24204 9.25 ug/L Se 77 206.671 7.501 0.000 0.16572 44.09 ug/L L Se 82 158.336 5.066 0.000 0.01396 250.25 ug/L Y 89 1483714.277 0.734 -10875.655 ug/L r Ag 107 707.368 16.290 0.000 0.00916 85.09 ug/L 1 Cd 111 1046.369 2.198 -0.000 -0.04844 12.30 ug/L I Cd 114 242.051 7.710 0.000 0.00012 1925.18 ug/L i> In 115 1646679.423 0.538 1646679.423 ug/L I Sb 121 665.698 1.087 0.000 0.04287 1.69 ug/L L Sb 123 502.790 8.004 0.000 0.04193 11.06 ug/L r Ba 135 47794.120 0.705 0.020 14.03899 0.89 ug/L I Ba 137 83218.104 2.204 0.035 14.02563 3.13 ug/L l> Tb 159 2376149.555 1.211 2376149.555 ug/L I Ho 165 2449851.418 1.241 0.000 ug/L I T1 205 583.691 4.678 0.000 0.00277 37.09 ug/L L Pb 208 4510.150 1.573 -0.002 -0.11987 1.79 ug/L
QC Calculated Values /knaiyte Mass QC Std % Recovery Int Std % Recovery Spike % Recovery Dilution % Diff Dup. Rei. % Diff r Be 9 1> Sc-1 45 100.320 I Cr 52
Sample ID: AE03504 Report Date/Time: Tuesday. March 19, 2002 11:06:12 Page 1
NYC-WTC_000077329
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000077357
Summary of water sample results for metals analysis using Method 200.8 conducted on March 19, 2002.
1 shared topics · Same agency, volume and box · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000077433
Summary of water sample results for metals analysis using Method 200.8 conducted on March 21, 2002.
1 shared topics · Same agency, volume and box · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000077205
Summary of water sample results for metals analysis using Method 200.8 conducted on March 15, 2002.
1 shared topics · Same agency, volume and box · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000076792
Summary of water sample results for metals analysis using Method 200.8 conducted on March 6, 2002.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000077560
Laboratory report from Westchester County Dept of Labs and Research detailing Method 200.8 metal concentrations in water samples dated March 21, 2002.
1 shared topics · Same agency, volume and box · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000053212
Daily instrument calibration and performance verification log for ICPMS equipment conducted on May 9, 2002.
1 shared topics · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000040976
Daily instrument performance verification log for ICPMS analysis including intensity and standard deviation data for multiple elements.
1 shared topics · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000052963
Daily instrument calibration and performance verification log for ICPMS equipment conducted on May 3, 2002.
1 shared topics · similarity 0.989
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000053630
Laboratory analysis results for a Westchester County Department of Labs and Research sample processed on May 15, 2002.
1 shared topics · similarity 0.988
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000053505
Daily instrument calibration and performance verification log for ICPMS equipment conducted on May 15, 2002.
1 shared topics · similarity 0.987
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000053939
Daily instrument calibration and performance verification log for ICPMS equipment conducted on May 21, 2002.
1 shared topics · similarity 0.986
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000054157
Daily instrument calibration and performance verification log for ICPMS equipment conducted on May 22, 2002.
1 shared topics · similarity 0.986
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
Page similarity is temporarily unavailable or this page has no indexed vector.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000077277
Administrative record from the Department of Environmental Protection regarding World Trade Center activities on March 19, 2002.
Filed in the same folder
Summary of water sample results for metals analysis using Method 200.8 conducted on March 19, 2002.
Similar indexed content
Summary of water sample results for metals analysis using Method 200.8 conducted on March 21, 2002.
Similar indexed content
Summary of water sample results for metals analysis using Method 200.8 conducted on March 15, 2002.
Similar indexed content
Summary of water sample results for metals analysis using Method 200.8 conducted on March 6, 2002.
Similar indexed content