Water analysis report, NYC DEP, Oct-Nov 2001

Machine-extracted title · confidence 95%

Laboratory analysis report for drinking water samples collected October 22, 2001, testing for silver and aluminum.

NYC-WTC_000072777–000072783

Folder label: “25873

Page image
Scanned page image, NYC-WTC_000072783
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

REPORT OF ANALYSIS Westchester County Department of Labs and Research 2 Dana Road Valhalla, New York

Agency: New York City DEP DWQC Sample HILLVIEW BX Distribution Laboratory 96-05 Horace Harding Ex. Corona N.Y. 11368 Sample 58 Dr. Ian Hurley ID of Source: Received LK Collection 10/22/2001 AT 9:25:00 Bottle c0376,q9796.24,9447,p9410,943 Submitted 10/22/2001 AT Collected By: TIGLAO Sample Type: POT_DW Comment: PWS No.: Source Code: Type Descriptor: Sample chilled on arrival? : YES Report

Sample No. AD25874 Method Test Description Results Units MDL Analyzed on Validator bis(2-Ethylhexyl)phthalate 2.1 ug/L 0.60 11/1/2001 DLV Butachlor < MDL ug/L 0.40 11/1/2001 DLV EPTC <MDL ug/L 1.0 11/1/2001 DLV Hexachlorobenzene <MDL ug/L 0.10 11/1/2001 DLV Hexachlorocyclopentadiene < MDL ug/L 0.10 11/1/2001 DLV Metolachlor < MDL ug/L 0.75 11/1/2001 DLV Metribuzin <MDL ug/L 0.15 11/1/2001 DLV Molinate <MDL ug/L 0.90 11/1/2001 DLV Simazine < MDL ug/L 0.40 11/1/2001 DLV Terbacil <MDL ug/L 2.0 11/1/2001 DLV Recoveries for 2 of the 18 compounds in the MDL Standard were above thier acceptance ranges. Recoveries for 3 of the 18 compounds in the LCS Standard were outside of their acceptance ranges. Recoveries for 4 of the 18 compounds in the Spiked Sample were outside of their acceptance ranges. The recovery for 1 of the 3 Surrogate Standards in this sample was below its acceptance range. GCMS Scan For Unknowns Other unknown compounds ug/L 12/12/2001 DLV A scan of the extract prepared for the 508 analysis, from 35 to 550 amu using a mass spectrometer, does not reveal the presence of non-target compounds, except for 1,1,2,2-Tetrachloroethane at an estimated level of 0.48 ug/L and a fit of 95 out of 100. The Field Blank for this sample will be analyzed.

Approved Pam Dilsizian QA Officer Date Approved: 12/13/2001

Environmental Laboratories emailed Original 12/13/2001

NYS ELAP #10108 Page 7 of 7

NYC-WTC_000072783

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000072783Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →