NYC-WTC_000058600
Laboratory report showing GCMS blank analysis for volatile organic compounds on April 2, 2002.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗Laboratory report of a GCMS blank test conducted on April 5, 2002, showing non-detect levels for various organic compounds.
NYC-WTC_000059487–000059490Folder label: “GCMS X 3/12/02 A 4/2/02”

OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Quantitation Report (QT Reviewed)
Data File C:\HPCHEM\1\DATA\APRO10 2\CAL2 5.D Vial: 2 Acq On 1 Apr 2002 12:11 pm Operator: Sample Inst ': GC/MS 209 Mise Multiplr: 1.00 MS Integration Params: GOOFY.P Quant Time: Apr 4 12:08 2002 Quant Results File: GCMS0308.RES
Quant Method : C:\HPCHEM\1\METHODS\GCMS0308.M (RTE Integrator) Title : 209 625/TCLP calibration table Last Update : Fri Mar 29 10:31:28 2002 Response via : Initial Calibration DataAcq Meth : GCMS0308
Compound R.T. Qlon Response Cone Unit Qvalue
30) N-Nitrosodiphenylamine 23.24 168 938539 24.59 ug/1 # 82 31) 4-Bromophenyl-phenylether 24.30 248 595769 26.56 ug/1 92 32) Hexachlorobenzene 24.74 284 705961 27.10 ug/1 # 88 33) Phenanthrene 25.73 178 3040701 24.91 ug/1 99 34) Anthracene 25.85 178 2839092 23.46 ug/1 99 35) Di-n-butylphthalate 27.62 149 3748467 24.40 ug/1 # 99 36) Fluoranthene 29.34 202 3069119 J3.,^ug/1 # 93 39) Pyrene 30.02 202 3067324 33.34j5g/l 94 40) Butylbenzylphthalate 32.14 149 1375675 '^jy.aUug/i 98 41) Benzo(a)anthracene 33.66 228 1875648 24.52 ug/1 100 42) Bis(2-ethylhexyl)phthalate 33.91 149 1571383 24.54 ug/1 96 43) Chrysene 33.79 228 1860669 24.80 ug/1 99 45) Di-n-Octylphthalate 35.66 149 2145233 30.97 ug/1 # 96 46) Benzo(b)fluoranthene 36.77 252 1373676 28.62 ug/1 98 47) Benzo(k)fluoranthene 36.83 252 1432434m 30.61 ug/1 48) Benzo(a)pyrene 37.76 252 1060178 24.23 ug/1 # 97 49) Indeno(1,2,3-cd)pyrene 42.09 276 1007174 19.06 ug/1 96 50) Dibenz(a,h)anthracene 42.15 278 779602 19.06 ug/1 97 51) Benzo(g,h,i)perylene 43.33 276 806903 18.73 ug/1 97
(#) = qualifier out of range (m) = manual integration CAL25.D GCMS0403.M Fri Apr 05 09:35:59 2002 Page 2
NYC-WTC_000059489
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000058600
Laboratory report showing GCMS blank analysis for volatile organic compounds on April 2, 2002.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000058826
Laboratory report showing GCMS calibration analysis for volatile organic compounds on April 2, 2002.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000058254
Calibration analysis report for sample AE04733 conducted April 1, 2002, listing concentrations of target compounds.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000059114
Calibration results for specific volatile organic compounds used to verify GCMS instrument performance in April 2002.
1 shared topics · Same agency, volume and box · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000059218
Calibration data for gas chromatography mass spectrometry analysis of volatile organic compounds dated April 4, 2002.
1 shared topics · Same agency, volume and box · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000058360
Laboratory report showing non-detectable levels of volatile organic compounds in a method blank analyzed on March 29, 2002.
1 shared topics · Same agency, volume and box · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000058175
Analysis of reference standards for nitrosamines and VOCs with measured concentrations near target levels on March 29, 2002.
1 shared topics · Same agency, volume and box · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000058364
Laboratory report listing concentrations of target analytes in a reference standard analyzed on March 29, 2002.
1 shared topics · Same agency, volume and box · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000058907
Calibration results for specific volatile organic compounds used to verify GCMS instrument performance in April 2002.
1 shared topics · Same agency, volume and box · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000009566
Calibration standard analysis for sample AE00938 showing quantitative results for organic compounds.
1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000011707
Laboratory report of a GCMS blank run on March 27, 2002, listing target compounds and detection limits.
1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000037992
Log sheet recording sample preparation details including drip rates and pH for GCMS analysis in March 2002.
1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
Page similarity is temporarily unavailable or this page has no indexed vector.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000059471
Administrative record from the Department of Environmental Protection regarding World Trade Center activities in early 2002.
Filed in the same folder
NYC-WTC_000059472
Single-page document from DEP Box 57 containing minimal visible text, likely part of a larger environmental record series.
Filed in the same folder
NYC-WTC_000059473
Data sheet recording water quality parameters including drip rate, pH, and counts for samples analyzed in early 2002.
Filed in the same folder
NYC-WTC_000059478
Instrument calibration record using DFTPP standard to verify GCMS performance for analytical testing on April 1, 2002.
Filed in the same folder
NYC-WTC_000059491
Calibration data sheet listing retention times and response factors for multiple organic compounds analyzed on April 5, 2002.
Filed in the same folder