NYC-WTC_000054548
Document page from the Department of Environmental Protection ICPMS series dated May 30, 2002.
1 shared topics · Same agency, volume and box · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗Daily instrument calibration and performance verification log for ICPMS equipment conducted on May 24, 2002.
NYC-WTC_000054375–000054546Folder label: “ICPMS 5/24/02”

OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
WESTCHESTER COUNTY DEPT OF LABS AND RESEARCH Method 200.8 - Summary Report Sample ID: AE11278 Sample Date/Time: Friday, May 24, 2002 10:28:24 Sample Type: Sample Sample Description: Number of Replicates: 3 Method File: c:\winnt\profiles\lrd1\elandata\Method\_NEWN.mth Dataset File: c:\winnt\profiles\lrd1\elandata\Dataset\new york city\AE11278.362 Aliquot Volume (mL): Diluted To Volume (mL):
Concentration Results Analyte Mass Meas. Intens. Mean Meas. Intens. RSD Net Intens. Mean Cone. Mean Cone. RSD Sample Unit Be 9 7.667 45.807 0.000 0.00787 113.92 ug/L Li 6 55499.117 0.630 55499.117 ug/L Sc-1 45 418409.699 1.766 418409.699 ug/L Cr 52 7669.310 0.490 0.003 0.12326 14.61 ug/L Cr 53 2142.941 2.726 0.004 1.64533 5.55 ug/L Mn 55 1162730.862 0.581 2.777 80.78352 2.17 ug/L Co 59 825.046 4.305 0.002 0.06617 5.26 ug/L Ni 60 2406.009 2.985 0.006 1.13220 2.43 ug/L Cu 63 9149.694 1.395 0.021 2.01983 1.87 ug/L Cu 65 4053.944 2.066 0.009 1.82819 3.94 ug/L Zn 66 3573.405 2.444 0.033 1.97208 3.77 ug/L Zn 67 803.377 3.369 0.008 2.58296 3.05 ug/L Zn 68 3311.636 1.243 0.032 2.59503 2.23 ug/L > Ge 72 87148.637 1.260 87148.637 ug/L As 75 12946.266 1.706 0.007 0.35072 9.59 ug/L Se 77 1686.995 0.817 0.002 0.85792 11.55 ug/L Se 82 -20.408 393.249 0.002 0.66397 60.56 ug/L As-1 75 1120.747 0.225 1012.412 0.53923 0.25 ug/L Kr 83 4647.902 3.030 -199.772 ug/L Ag 107 361.344 20.963 0.000 0.00955 88.76 ug/L Cd 111 43.667 14.544 0.000 0.00798 31.56 ug/L Cd 114 86.851 16.142 0.000 0.00702 34.09 ug/L in 115 1159129.462 0.584 1159129.462 ug/L Sb 121 635.029 7.581 0.001 0.07691 8.43 ug/L Sb 123 500.298 1.702 0.000 0.08049 1.23 ug/L Ba 135 68818.518 0.324 0.039 29.70136 0.68 ug/L Ba 137 119794.055 1.251 0.068 29.58406 1.05 ug/L Ho 165 1795708.269 0.852 0.005 ug/L > Tb 159 1772064.367 0.787 1772064.367 ug/L Hg 201 46.667 16.225 0.000 0.00523 115.73 ug/L Hg 202 96.335 5.121 0.000 0.00431 37.32 ug/L TI 205 393.013 17.100 -0.000 -0.00660 35.68 ug/L Pb 208 5437.025 0.998 0.002 0.10138 0.41 ug/L
Sample ID: AE11278 Report Date/Time: Friday, May 24, 2002 10:30:20 Page 1
NYC-WTC_000054421
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000054548
Document page from the Department of Environmental Protection ICPMS series dated May 30, 2002.
1 shared topics · Same agency, volume and box · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000054157
Daily instrument calibration and performance verification log for ICPMS equipment conducted on May 22, 2002.
1 shared topics · Same agency, volume and box · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000053939
Daily instrument calibration and performance verification log for ICPMS equipment conducted on May 21, 2002.
1 shared topics · Same agency, volume and box · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000053706
Daily instrument calibration and performance verification log for ICPMS equipment conducted on May 16, 2002.
1 shared topics · Same agency, volume and box · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000054670
Document page from the Department of Environmental Protection ICPMS series dated May 31, 2002.
1 shared topics · Same agency, volume and box · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000054747
Westchester County Department of Labs and Research report detailing elemental analysis results for sample AE12151 using ICPMS Method 200.8.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000054886
Westchester County Department of Labs and Research report detailing elemental analysis results for sample ID [name] using ICPMS Method 200.8.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000053630
Laboratory analysis results for a Westchester County Department of Labs and Research sample processed on May 15, 2002.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000053505
Daily instrument calibration and performance verification log for ICPMS equipment conducted on May 15, 2002.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000053212
Daily instrument calibration and performance verification log for ICPMS equipment conducted on May 9, 2002.
Same agency, volume and box · similarity 0.992
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000052963
Daily instrument calibration and performance verification log for ICPMS equipment conducted on May 3, 2002.
Same agency, volume and box · similarity 0.986
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000077357
Summary of water sample results for metals analysis using Method 200.8 conducted on March 19, 2002.
Similar document embedding; no shared entity or topic indexed. · similarity 0.986
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000054157
Daily instrument calibration and performance verification log for ICPMS equipment conducted on May 22, 2002.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000054157
Daily instrument calibration and performance verification log for ICPMS equipment conducted on May 22, 2002.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000053939
Daily instrument calibration and performance verification log for ICPMS equipment conducted on May 21, 2002.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000054548
Document page from the Department of Environmental Protection ICPMS series dated May 30, 2002.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000054548
Document page from the Department of Environmental Protection ICPMS series dated May 30, 2002.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000054548
Document page from the Department of Environmental Protection ICPMS series dated May 30, 2002.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000054374
Document containing ICPMS analytical data or results from May 24, 2002.
Filed in the same folder
NYC-WTC_000054548
Document page from the Department of Environmental Protection ICPMS series dated May 30, 2002.
Similar indexed content
NYC-WTC_000054157
Daily instrument calibration and performance verification log for ICPMS equipment conducted on May 22, 2002.
Similar indexed content
NYC-WTC_000053939
Daily instrument calibration and performance verification log for ICPMS equipment conducted on May 21, 2002.
Similar indexed content
NYC-WTC_000053706
Daily instrument calibration and performance verification log for ICPMS equipment conducted on May 16, 2002.
Similar indexed content