NYC-WTC_000054548
Document page from the Department of Environmental Protection ICPMS series dated May 30, 2002.
1 shared topics · Same agency, volume and box · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗Daily instrument calibration and performance verification log for ICPMS equipment conducted on May 24, 2002.
NYC-WTC_000054375–000054546Folder label: “ICPMS 5/24/02”

OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
WESTCHESTER COUNTY DEPT OF LABS AND RESEARCH Method 200.8 - Summary Report Sample ID: AE11903 Sample Date/Time: Friday, May 24, 2002 13:02:17 Sample Type: Sample Sample Description: Number of Replicates: 3 Method File: c:\winnt\profiles\lrd1\elandata\Method\_NEWN.mth Dataset File: c:\winnt\profiles\lrd1\elandata\Dataset\new york city\AE11903.397 Aliquot Volume (mL): Diluted To Volume (mL):
Concentration Results Analyte Mass Meas. Intens. Mean Meas. Intens. RSD Net Intens. Mean Cone. Mean Cone. RSD Sample Unit Be 9 8.000 21.651 0.000 0.01160 37.54 ug/L Li 6 55837.850 0.460 55837.850 ug/L Se-1 45 402968.132 1.166 402968.132 ug/L Cr 52 12098.837 2.572 0.015 0.70004 5.63 ug/L Cr 53 2311.984 4.734 0.004 1.65092 7.06 ug/L Mn 55 651461.228 0.656 1.615 46.97503 0.55 ug/L Co 59 753.706 6.176 0.002 0.06543 6.90 ug/L Ni 60 2469.693 0.466 0.006 1.20677 1.43 ug/L Cu 63 10883.287 1.144 0.026 2.50313 2.17 ug/L Cu 65 4886.695 0.373 0.012 2.30277 1.18 ug/L Zn 66 1968.566 0.408 0.016 0.95036 1.14 ug/L Zn 67 562.690 7.602 0.005 1.68865 11.08 ug/L Zn 68 2092.262 5.398 0.019 1.56907 7.50 ug/L > Ge 72 82270.746 0.440 82270.746 ug/L As 75 12811.736 1.178 0.004 0.18178 44.80 ug/L Se 77 1671.497 1.430 0.001 0.70009 15.25 ug/L Se 82 -52.784 62.120 -0.001 -0.30041 57.71 ug/L As-1 75 1052.071 1.776 944.070 0.50283 1.98 ug/L Kr 83 4612.550 1.869 -134.738 ug/L Ag 107 227.005 4.339 -0.000 -0.00504 19.93 ug/L Cd 111 37.667 29.603 0.000 0.00946 52.96 ug/L Cd 114 76.179 8.319 0.000 0.00707 18.31 ug/L > In 115 1074901.439 0.656 1074901.439 ug/L Sb 121 502.352 1.934 0.000 0.06423 2.80 ug/L Sb 123 384.079 7.865 0.000 0.06481 8.94 ug/L Ba 135 64095.170 1.660 0.039 29.98964 1.74 ug/L Ba 137 111202.107 0.492 0.068 29.77471 1.05 ug/L Ho 165 1648785.557 0.624 -0.017 ug/L > Tb 159 1634445.643 0.581 1634445.643 ug/L Hg 201 37.667 11.971 0.000 0.00290 132.36 ug/L Hg 202 67.001 6.840 -0.000 -0.00309 59.01 ug/L TI 205 299.341 20.584 -0.000 -0.00774 31.68 ug/L Pb 208 8716.070 2.712 0.004 0.20737 3.51 ug/L
Sample ID:AE11903 Report Date/Time: Friday, May 24, 2002 13:04:13 Page 1
NYC-WTC_000054526
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000054548
Document page from the Department of Environmental Protection ICPMS series dated May 30, 2002.
1 shared topics · Same agency, volume and box · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000054157
Daily instrument calibration and performance verification log for ICPMS equipment conducted on May 22, 2002.
1 shared topics · Same agency, volume and box · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000053939
Daily instrument calibration and performance verification log for ICPMS equipment conducted on May 21, 2002.
1 shared topics · Same agency, volume and box · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000053706
Daily instrument calibration and performance verification log for ICPMS equipment conducted on May 16, 2002.
1 shared topics · Same agency, volume and box · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000054670
Document page from the Department of Environmental Protection ICPMS series dated May 31, 2002.
1 shared topics · Same agency, volume and box · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000054747
Westchester County Department of Labs and Research report detailing elemental analysis results for sample AE12151 using ICPMS Method 200.8.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000054886
Westchester County Department of Labs and Research report detailing elemental analysis results for sample ID [name] using ICPMS Method 200.8.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000053630
Laboratory analysis results for a Westchester County Department of Labs and Research sample processed on May 15, 2002.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000053505
Daily instrument calibration and performance verification log for ICPMS equipment conducted on May 15, 2002.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000053212
Daily instrument calibration and performance verification log for ICPMS equipment conducted on May 9, 2002.
Same agency, volume and box · similarity 0.992
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000052963
Daily instrument calibration and performance verification log for ICPMS equipment conducted on May 3, 2002.
Same agency, volume and box · similarity 0.986
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000077357
Summary of water sample results for metals analysis using Method 200.8 conducted on March 19, 2002.
Similar document embedding; no shared entity or topic indexed. · similarity 0.986
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000053939
Daily instrument calibration and performance verification log for ICPMS equipment conducted on May 21, 2002.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000054157
Daily instrument calibration and performance verification log for ICPMS equipment conducted on May 22, 2002.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000054157
Daily instrument calibration and performance verification log for ICPMS equipment conducted on May 22, 2002.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000054157
Daily instrument calibration and performance verification log for ICPMS equipment conducted on May 22, 2002.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000054548
Document page from the Department of Environmental Protection ICPMS series dated May 30, 2002.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000053939
Daily instrument calibration and performance verification log for ICPMS equipment conducted on May 21, 2002.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000054374
Document containing ICPMS analytical data or results from May 24, 2002.
Filed in the same folder
NYC-WTC_000054548
Document page from the Department of Environmental Protection ICPMS series dated May 30, 2002.
Similar indexed content
NYC-WTC_000054157
Daily instrument calibration and performance verification log for ICPMS equipment conducted on May 22, 2002.
Similar indexed content
NYC-WTC_000053939
Daily instrument calibration and performance verification log for ICPMS equipment conducted on May 21, 2002.
Similar indexed content
NYC-WTC_000053706
Daily instrument calibration and performance verification log for ICPMS equipment conducted on May 16, 2002.
Similar indexed content