Daily instrument calibration and performance verification log for ICPMS equipment conducted on May 21, 2002.
1 shared topics · Same agency, volume and box · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗Daily instrument calibration and performance verification log for ICPMS equipment conducted on May 22, 2002.
NYC-WTC_000054157–000054373Folder label: “ICPMS 5/22/02”

OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
WESTCHESTER COUNTY DEPT OF LABS AND RESEARCH Method 200.8 - Summary Report Sample ID: AE11420 Sample Date/Time: Wednesday, May 22, 2002 11:29:05 Sample Type: Sample Sample Description: Number of Replicates: 3 Method File: c:\winnt\profiles\lrd1\elandata\Method\_NEWN.mth Dataset File: c:\wlnnt\profiles\lrd1\elandata\Dataset\new york city\AE11420.308 Aliquot Volume (mL): Diluted To Volume (mL):
Concentration Results Analyte Mass Meas. Intens. Mean Meas. Intens. RSD Net Intens. Mean Cone. Mean Cone. RSD Sample Unit Be 9 8.667 17.625 0.000 0.00288 156.75 ug/L Li 6 44495.415 1.318 44495.415 ug/L Se-1 45 332950.137 1.419 332950.137 ug/L Cr 52 7941.548 2.458 0.008 0.38571 11.22 ug/L Cr 53 1169.087 3.264 0.002 0.74651 7.64 ug/L Mn 55 324022.566 1.356 0.970 28.31087 1.71 ug/L Co 59 309.675 9.829 0.001 0.02118 15.48 ug/L Ni 60 636.362 5.625 0.002 0.34958 5.02 ug/L Cu 63 46283.651 0.564 0.139 12.19298 1.39 ug/L Cu 65 22570.880 1.372 0.068 12.07348 1.31 ug/L Zn 66 6597.127 2.646 0.077 4.66930 2.75 ug/L Zn 67 1206.092 0.287 0.014 4.75221 0.47 ug/L Zn •68 5176.860 3.359 0.061 4.91990 3.65 ug/L > Ge 72 78155.968 0.219 78155.968 ug/L As 75 11540.250 1.098 0.010 0.49808 15.02 ug/L Se 77 1428.163 1.875 0.001 0.51884 33.56 ug/L Se 82 -24.602 164.521 -0.000 -0.06810 347.74 ug/L As-1 75 898.720 3.563 741.717 0.43265 4.32 ug/L Kr 83 4056.279 1.981 -585.954 ug/L Ag 107 129.669 9.643 -0.000 -0.05809 2.89 ug/L Cd 111 62.001 12.177 0.000 0.01603 20.61 ug/L Cd 114 138.608 5.801 0.000 0.01908 10.81 ug/L > In 115 1096688.460 2.337 1096688.460 ug/L Sb 121 430.681 8.399 0.000 0.05123 8.49 ug/L Sb 123 317.197 5.744 0.000 0.04827 8.47 ug/L Ba 135 38902.116 0.720 0.023 17.52845 0.96 ug/L Ba 137 68220.369 0.723 0.040 17.59713 1.65 ug/L Ho 165 1732221.413 0.109 0.016 ug/L Tb 159 1701690.712 0.928 1701690.712 ug/L Hg 201 41.667 21.511 0.000 0.01013 73.38 ug/L Hg 202 95.001 10.042 0.000 0.01076 34.07 ug/L TI 205 423.681 4.104 -0.000 -0.00633 8.11 ug/L Pb 208 15535.686 1.822 0.008 0.38232 1.32 ug/L
Sample ID: AE11420 Report Date/Time: Wednesday, May 22,2002 11:31:01 Page 1
NYC-WTC_000054257
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000053939
Daily instrument calibration and performance verification log for ICPMS equipment conducted on May 21, 2002.
1 shared topics · Same agency, volume and box · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000054548
Document page from the Department of Environmental Protection ICPMS series dated May 30, 2002.
1 shared topics · Same agency, volume and box · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000054375
Daily instrument calibration and performance verification log for ICPMS equipment conducted on May 24, 2002.
1 shared topics · Same agency, volume and box · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000053706
Daily instrument calibration and performance verification log for ICPMS equipment conducted on May 16, 2002.
1 shared topics · Same agency, volume and box · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000054670
Document page from the Department of Environmental Protection ICPMS series dated May 31, 2002.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000054747
Westchester County Department of Labs and Research report detailing elemental analysis results for sample AE12151 using ICPMS Method 200.8.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000053630
Laboratory analysis results for a Westchester County Department of Labs and Research sample processed on May 15, 2002.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000053505
Daily instrument calibration and performance verification log for ICPMS equipment conducted on May 15, 2002.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000054886
Westchester County Department of Labs and Research report detailing elemental analysis results for sample ID [name] using ICPMS Method 200.8.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000053212
Daily instrument calibration and performance verification log for ICPMS equipment conducted on May 9, 2002.
1 shared topics · Same agency, volume and box · similarity 0.992
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000052963
Daily instrument calibration and performance verification log for ICPMS equipment conducted on May 3, 2002.
1 shared topics · Same agency, volume and box · similarity 0.986
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000077278
Summary of water sample results for metals analysis using Method 200.8 conducted on March 19, 2002.
1 shared topics · similarity 0.986
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
Page similarity is temporarily unavailable or this page has no indexed vector.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000054156
Document containing ICPMS analytical data or results from May 22, 2002.
Filed in the same folder
NYC-WTC_000053939
Daily instrument calibration and performance verification log for ICPMS equipment conducted on May 21, 2002.
Similar indexed content
NYC-WTC_000054548
Document page from the Department of Environmental Protection ICPMS series dated May 30, 2002.
Similar indexed content
NYC-WTC_000054375
Daily instrument calibration and performance verification log for ICPMS equipment conducted on May 24, 2002.
Similar indexed content
NYC-WTC_000053706
Daily instrument calibration and performance verification log for ICPMS equipment conducted on May 16, 2002.
Similar indexed content