NYC 9/11 Public Portal Document
Data File : C:\HPCHEM\1\DATA\FEB1402\1044.D Vial: 7
Acq On : 14 Feb 2002 3:54 pm Operator: 209 GALOS
Sample : GC/MS SCAN 1/15 Inst : GC/MS 209
Mise : Multiplr: 1.00
MS Integration Params: GOOFY.P
Quant Time: Feb 19 12:50 2002 <Quant Results File: GCMS0208.RES
Quant Method : C:\HPCHEM\1\METHODS\GCMS0208.M (RTE Integrator)
Title : 209 625/TCLP calibration table
Last Update : Wed Feb 13 11:43:23 2002
Response via : Initial Calibration
DataAcq Meth : GCMS0208
Internal Standards R.T. Qlon Response Cone Units Dev(Min)
1) 1,4-Dichlorobenzene-d4 12.34 152 276890 20.00 ug/1 -0.01
10) Naphthalene-d8 15.99 136 1070267 20.00 ug/1 -0.01
17) Acenaphthene-diO 21.30 164 571561 20.00 ug/1 -0.01
29) Phenanthrene-diO 25.76 188 843803 20.00 ug/1 -0.01
38) Chrysene-dl2 33.82 240 579797 20.00 ug/1 -0.02
44) Perylene-dl2 38.10 264 352761 20.00 ug/1 -0.02
System Monitoring Compounds
37) 2,4-DDD 30.83 235 45005 5.31 ug/mL 0.33
Spiked Amount 5.000 Recovery = 106.20%
Target Compounds Qvalue
2) N-nitroso-dimethyl amine 0.00 74 0 N.D.
3) bis(2-Chloroethyl)ether 0.00 93 0 N.D. ■ I
4) 1,3-Dichlorobenzene 0.00 146 0 N.D. rW
5) 1,4-Dichlorobenzene 0.00 146 0 N.D.
6) 1,2-Dichlorobenzene 0.00 146 0 N.D.
7) 2,21 -oxybis(1-Chloropropan 0.00 45 0 N.D.
8) N-Nitroso-di-n-propylamine 0.00 70 0 N.D.
9) Hexachloroethane 0.00 117 0 N.D.
11) Nitrobenzene 0.00 77 0 N.D.
12) 1sophorone 0.00 82 0 N.D.
13) bis(2-Chloroethoxy)methane 0.00 93 0 N.D.
14) 1,2,4-Trichlorobenzene 0.00 180 0 N.D.
15) Naphthalene 16.04 128 401 N.D.
16) Hexachlorobutadiene 0.00 225 0 N.D.
18) Hexachlorocyclopentadiene 0.00 237 0 N.D.
19) 2-Chloronaphthalene 0.00 162 0 N.D.
20) Dimethylphthalate 0.00 163 0 N.D.
21) 2,6-Dinitrotoluene 0.00 165 0 N.D.
22) Acenaphthylene 0.00 152 0 N.D.
2 3) Acenaphthene 0.00 153 0 N.D.
24) 2,4-Dinitrotoluene 0.00 165 0 N.D.
25) Diethylphthalate 22.77 149 477 N.D.
26) 4-Chlorophenyl-phenylether 0.00 204 0 N.D.
27) Fluorene 0.00 166 0 N.D.
28) Azobenzen/ 1,2-Diphenylhyd 0.00 77 0 N.D.
(#) = qualifier out of range (m) = manual integration
1044.D GCMS0308.M Thu Mar 14 15:23:59 2002 Page 1
NYC-WTC_000052614
OCR can misread numbers and units. Confirm readings against the page image before using them.