Quantitation Report (QT Reviewed)

Data File : C:\MSDCHEM\l\DATA\020513\10132.D Vial: 19 Acq On : 14 May 2002 6:22 am Operator: Nefliu Sample : sample Inst : Instrumen Mise : Multiplr: 1.00 MS Integration Params: rteint.e Quant Time: May 14 16:00:25 2002 Quant Results File: SCAN020507.RE

Quant Method : C:\MSDCHEM\1\METHODS\SCAN020507.M (RTE Integrator) Title : Method 508 GC/MS Scan Last Update : Thu May 09 09:21:01 2002 Response via : Initial Calibration DataAcq Meth : 508SCAN1

Internal Standards R.T. Qlon Response Cone Units Dev(Min)

1) 1,4-Dichlorobenzene-d4 11.38 152 465261 40.00 ug/1 -0.01 10) Naphthalene-d8 16.53 136 1747558 40.00 ug/1 -0.04 17) Acenaphthene-diO 24.46 164 928242 40.00 ug/1 -0.02 30) Phenanthrene-diO 31.72 188 1577885 40.00 ug/1 -0.02 38) Chrysene-dl2 39.93 240 1247856 40.00 ug/1 -0.05 44) Perylene-dl2 43.15 264 768835 40.00 ug/1 -0.03

System Monitoring Compounds 27) TCMX 27.54 207 71586m 9.65 ug/1 -0.04 Spiked Amount 10.000 Recovery = 96.50%

Target Compounds Qvalue 29) Azobenzene 28.10 77 67 0.00 ug/1 61 43) Bis(2-ethylhexyl )phthalate 40.52 149 5224 0.20 ug/1 95

(#) = qualifier out of range (m) = manual integration (+) = signals summed 10132.D SCAN020507.M Wed May 15 09:54:17 2002 Page 1

NYC-WTC_000046149

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000046149Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →