Quantitation Report (QT Reviewed)
Data File C:\HPCHEM\l\DATA\MAY0102\9565.D Vial: 4 Acq On 1 May 2002 10:51 am Operator: Sample gc/ms scan 4/23 Inst : 209 Mise Multiplr: 1.00 MS Integration Params: GOOFY.P Quant Time: May 1 11:42 2002 Quant Results File: GCMS0501.RES
Quant Method : C:\HPCHEM\1\METHODS\GCMS0501.M (RTE Integrator) Title : 209 625/TCLP calibration table Last Update : Wed May 01 10:40:31 2002 Response via : Initial Calibration DataAcq Meth : GCMS0501
Internal Standards R.T. Qlon Response Cone Units Dev(Min)
1) 1,4-Dichlorobenzene-d4 12.21 152 352616 40.00 ug/1 0.00 10) Naphthalene-d8 15.84 136 1298969 40.00 ug/1 -0.02 17) Acenaphthene-dlO 21.14 164 697786 40.00 ug/1 0.00 30) Phenanthrene-diO 25.59 188 981989 40.00 ug/1 0.00 38) Chrysene-dl2 33.64 240 603210 40.00 ug/1 -0.02 44) Perylene-dl2 37.87 264 360218 40.00 ug/1 -0.02
System Monitoring Compounds 2 8) TCMX 23.28 209 33231 9.78 ug/L -0.02 Spiked Amount 10.000 Recovery = 97.80%
Target Compounds Qvalue 2) N-nitroso-dimethyl amine 0.00 74 0 N.D. 3) bis(2-Chloroethyl)ether 0.00 93 0 N.D. 4) 1,3-Dichlorobenzene 0.00 146 0 N.D. 5) 1,4-Dichlorobenzene 0.00 146 0 N.D. 6) 1,2-Dichlorobenzene 0.00 146 0 N.D. 7) 2,21-oxybis(1-Chloropropan 0.00 45 0 N.D. 8) N-Nitroso-di-n-propylamine 0.00 70 0 N.D. 9) Hexachloroethane 0.00 117 0 N.D. 11) Nitrobenzene 0.00 77 0 N.D. 12) Isophorone 0.00 82 0 N.D. 13) bis(2-Chloroethoxy)methane 0.00 93 0 N.D. 14) 1,2,4-Trichlorobenzene 0.00 180 0 N.D. 15) Naphthalene 0.00 128 0 N.D. 16) Hexachlorobutadiene 0.00 225 0 N.D. 18) Hexachlorocyclopentadiene 0.00 237 0 N.D. 19) 2-Chloronaphthalene 0.00 162 0 N.D. 20) Dimethylphthalate 0.00 163 0 N.D. 21) 2,6-Dinitrotoluene 0.00 165 0 N.D. d 22) Acenaphthylene 0.00 152 0 N.D. 23) Acenaphthene 0.00 153 0 N.D. 24) 2,4-Dinitrotoluene 0.00 165 0 N.D. 25) Diethylphthalate 22.62 149 777 N.D. 26) 4-Chlorophenyl-phenylether 0.00 204 0 N.D. 27) Fluorene 0.00 166 0 N.D. 29) Azobenzen/ 1,2-Diphenylhyd 0.00 77 0 N.D. 31) N-Nitrosodiphenylamine 0.00 168 0 N.D. 32) 4-Bromophenyl-phenylether 0.00 248 0 N.D. 33) Hexachlorobenzene 0.00 284 0 N.D. 34) Phenanthrene 25.59 178 116 N.D.
(#) = qualifier out of range (m) = manual integration 9565.D GCMS0501.M Wed May 01 11:44:35 2002 Page 1
NYC-WTC_000044351
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000044338
Laboratory comment noting low recovery in initial GCMS scan of sample AE08264, resulting in re-extraction.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000044836
Laboratory report showing gas chromatography-mass spectrometry results for unidentified organic compounds in sample AE10165 on May 10, 2002.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000044804
Laboratory report documenting GCMS analysis of sample AE10159 conducted on May 10, 2002.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000044815
Laboratory report documenting GCMS analysis of sample AE10161 conducted on May 10, 2002.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000045386
GCMS analytical report for sample AE10522 showing unknown compounds and surrogate recovery data from May 22, 2002.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000043291
GCMS results for sample AE09521 showing surrogate recovery and unknown compounds dated May 6, 2002.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000044268
Laboratory report documenting GCMS analysis of sample AE07484 conducted on May 6, 2002, including surrogate recovery data.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000043310
GCMS results for sample AE09524 showing surrogate recovery and unknown compounds dated May 6, 2002.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000043352
GCMS results for sample AE07001 showing surrogate recovery and unknown compounds dated April 29, 2002.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000023316
Laboratory report showing GC/MS analysis results for sample AE09578 including surrogate recovery data on May 16, 2002.
1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000023811
Laboratory report of GCMS analysis for sample AE09676 conducted on May 23, 2002, showing surrogate recovery data.
1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000005473
Laboratory report listing unknown compounds and surrogate recovery data for sample AE02711.
1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000046294
Laboratory report showing GCMS calibration data for sample AE09585 generated on May 4-6, 2002.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000044360
Laboratory report documenting GCMS analysis of sample AE09566 conducted on May 6, 2002.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000043220
Laboratory report for DEP Box 25 showing GCMS analysis of sample AE06048 with unknown compounds and surrogate data from May 6, 2002.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000023754
Laboratory report of GCMS analysis for sample AE09654 conducted on May 23, 2002, showing surrogate recovery data.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000044369
Laboratory report documenting GCMS analysis of sample AE09567 conducted on May 6, 2002.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000043619
Laboratory report documenting GCMS analysis of sample AE08951 conducted on April 29, 2002, including detection of unknown compounds.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000044239
Single-page administrative log from DEP Box 25 covering GCMS X analyses dated between April 23 and April 26, 2002.
Filed in the same folder
NYC-WTC_000044240
Fragmented page from a GCMS record series dated between April 23 and April 26, 2002, likely containing analytical data.
Filed in the same folder
NYC-WTC_000044245
Laboratory report of a GCMS blank analysis (Sample AE07484) conducted on May 2, 2002, checking for background contamination.
Filed in the same folder
NYC-WTC_000044253
Calibration report listing quantified values for various organic compounds including nitrosamines and chlorobenzenes used for instrument verification.
Filed in the same folder
NYC-WTC_000044257
Calibration record for GCMS analysis using standard compounds, generated on April 26, 2002, to ensure instrument accuracy.
Filed in the same folder