NYC-WTC_000052963
Daily instrument calibration and performance verification log for ICPMS equipment conducted on May 3, 2002.
1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗Daily instrument performance verification log for ICPMS analysis including intensity and standard deviation data for multiple elements.
NYC-WTC_000040976–000041063Folder label: “ICPMS 4/23/02”

OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
WESTCHESTER COUNTY DEPT OF LABS AND RESEARCH Method 200.8 - Summary Report Sample ID: Standard 1 Sample Date/Time: Tuesday, April 23, 2002 09:15:59 Sample Type: Sample Sample Description: Number of Replicates: 3 . Method File: d:\elandata\Method\NYC.mth Dataset File: d:\elandata\Dataset\new york city\Standard 1.654 Aliquot Volume (mL): Diluted To Volume (mL):
Concentration Results Analyte Mass Meas. Intens. Mean Meas. Intens. RSD Net Intens. Mean Cone. Mean Gone. RSD Sample Unit Be 9 10311.616 1.935 0.022 30.00000 0.77 ug/L Se-1 45 464123.270 1.211 464123.270 ug/L Cr 52 261416.347 1.779 0.547 30.00000 0.73 ug/L Cr 53 30993.750 2.937 0.065 30.00000 1.78 ug/L Mn 55 398850.401 1.651 0.857 30.00000 0.94 ug/L Ni 60 64147.257 2.529 0.138 30.00000 1.33 ug/L Cu 63 146541.090 2.062 0.315 30.00000 0.97 ug/L Cu 65 72440.229 1.360 0.156 30.00000 0.56 ug/L Zn 66 46025.024 1.594 0.502 30.00000 1.09 ug/L Zn 67 8393.291 1.719 0.091 30.00000 1.53 ug/L Zn 68 34511.076 1.947 0.376 30.00000 0.55 ug/L Ge 72 90147.040 1.406 90147.040 ug/L As 75 53575.888 0.386 0.594 30.00000 1.37 ug/L Se 77 5070.804 0.601 0.055 30.00000 1.06 ug/L Se 82 6092.102 1.184 0.066 30.00000 2.45 ug/L Ag 107 306252.377 1.431 0.235 30.00000 1.83 ug/L Cd 111 78478.110 1.439 0.059 30.00000 1.86 ug/L Cd 114 185216.070 1.483 0.142 30.00000 1.19 ug/L In 115 1302765.619 1.071 1302765.619 ug/L Sb 121 263274.476 0.474 0.202 30.00000 0.76 ug/L Sb 123 204986.840 1.038 0.157 30.00000 1.86 ug/L Ba 135 81649.601 1.984 0.044 30.00000 0.80 ug/L Ba 137 143588.441 2.846 0.078 30.00000 2.28 ug/L > Tb 159 1838425.070 1.428 1838425.070 ug/L Ho 165 1818297.750 1.860 -0.003 ug/L Hg 201 2489.699 1.759 0.001 2.00000 1.96 ug/L Hg 202 5773.892 3.307 0.003 2.00000 1.93 ug/L TI 205 747061.604 0.855 0.406 30.00000 0.68 ug/L Pb 208 1003456.399 0.887 0.545 30.00000 0.54 ug/L
QC Calculated Values Analyte Mass QC Std % Recovery Int Std % Recovery Spike % Recovery Dilution % Diff Dup. Rei. % Diff ' Be 9 > Sc-1 45 Cr 52
Sample ID: Standard 1 Report Date/Time: Tuesday, April 23, 2002 09:17:52 Page 1
NYC-WTC_000040980
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
No available related records indexed in this group.
NYC-WTC_000052963
Daily instrument calibration and performance verification log for ICPMS equipment conducted on May 3, 2002.
1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000077433
Summary of water sample results for metals analysis using Method 200.8 conducted on March 21, 2002.
1 shared topics · similarity 0.992
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000077357
Summary of water sample results for metals analysis using Method 200.8 conducted on March 19, 2002.
1 shared topics · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000077278
Summary of water sample results for metals analysis using Method 200.8 conducted on March 19, 2002.
1 shared topics · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000077205
Summary of water sample results for metals analysis using Method 200.8 conducted on March 15, 2002.
1 shared topics · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000076792
Summary of water sample results for metals analysis using Method 200.8 conducted on March 6, 2002.
1 shared topics · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000053212
Daily instrument calibration and performance verification log for ICPMS equipment conducted on May 9, 2002.
1 shared topics · similarity 0.990
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000077560
Laboratory report from Westchester County Dept of Labs and Research detailing Method 200.8 metal concentrations in water samples dated March 21, 2002.
1 shared topics · similarity 0.987
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000053630
Laboratory analysis results for a Westchester County Department of Labs and Research sample processed on May 15, 2002.
1 shared topics · similarity 0.986
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000053505
Daily instrument calibration and performance verification log for ICPMS equipment conducted on May 15, 2002.
1 shared topics · similarity 0.986
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000054375
Daily instrument calibration and performance verification log for ICPMS equipment conducted on May 24, 2002.
1 shared topics · similarity 0.985
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000053939
Daily instrument calibration and performance verification log for ICPMS equipment conducted on May 21, 2002.
1 shared topics · similarity 0.985
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
Page similarity is temporarily unavailable or this page has no indexed vector.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000040975
Document containing ICPMS analytical data for the World Trade Center site from April 2002.
Filed in the same folder
NYC-WTC_000052963
Daily instrument calibration and performance verification log for ICPMS equipment conducted on May 3, 2002.
Similar indexed content
Summary of water sample results for metals analysis using Method 200.8 conducted on March 21, 2002.
Similar indexed content
Summary of water sample results for metals analysis using Method 200.8 conducted on March 19, 2002.
Similar indexed content
Summary of water sample results for metals analysis using Method 200.8 conducted on March 19, 2002.
Similar indexed content