NYC 9/11 Public Portal Document
Quantitation Report (QT Reviewed)
Data File : C:\HPCHEM\1\DATA\DEC1401\29792.D Vial: 17
Acq On : 15 Dec 2001 6:08 pm Operator: 209 GALOS
Sample : gems scan 12/10 a Inst : GC/MS 209
Mise : Multiplr: 1.00
MS Integration Params: GOOFY.P
Quant Time: Dec 15 18:57 2001 Quant Results File: GCMS1126.RES
Quant Method : C:\HPCHEM\1\METHODS\GCMS1126.M (RTE Integrator)
Title : 209 625/TCLP calibration table
Last Update : Fri Dec 14 12:19:30 2001
Response via : Initial Calibration
DataAcq Meth : GCMS1126
Internal Standards R.T. Qlon Response Cone Units Dev(Min)
1) 1,4-Dichlorobenzene-d4 11.67 152 976144 20.00 ug/1 -0.03
10) Naphthalene-d8 15.28 136 3745586 20.00 ug/1 -0.03
17) Acenaphthene-dlO 20.55 164 1879592 20.00 ug/1 -0.03
29) Phenanthrene-dlO 24.97 188 2712617 20.00 ug/1 -0.02
38) Chrysene-dl2 33.01 240 1713742 20.00 ug/1 -0.03
44) Perylene-dl2 37.10 264 1117600 20.00 ug/1 -0.02
System Monitoring Compounds
37) 2,4-DDD 30.05 235 190882 4.86 ug/mL -0.02
Spiked Amount 5.000 Recovery = 97.20%
Target Compounds Qvalue
2) N-nitroso-dimethyl amine 5.14 74 392 N.D.
3) bis(2-Chloroethyl)ether 0.00 93 0 N.D.
4) 1,3-Dichlorobenzene 0.00 146 0 N.D.
5) 1,4-Dichlorobenzene 0.00 146 0 N.D.
6) 1,2-Dichlorobenzene 0.00 146 0 N.D.
7) 2,2‘-oxybis(1-Chloropropan 0.00 45 0 N.D.
8) N-Nitroso-di-n-propylamine 0.00 70 0 N.D.
9) Hexachloroethane 0.00 117 0 N.D.
11) Nitrobenzene 0.00 77 0 N.D.
12) Isophorone 0.00 82 0 N.D.
13) bis(2-Chloroethoxy)methane 0.00 93 0 N.D.
14) 1,2,4-Trichlorobenzene 0.00 180 0 N.D.
15) Naphthalene 15.33 128 1024 N.D.
16) Hexachlorobutadiene 0.00 225 0 N.D.
18) Hexachlorocyclopentadiene 0.00 237 0 N.D.
19) 2-Chloronaphthalene 0.00 162 0 N.D.
20) Dimethylphthalate 0.00 163 0 N.D.
21) 2,6-Dinitrotoluene 0.00 165 0 N.D.
22) Acenaphthylene 0.00 152 0 N.D.
23) Acenaphthene 0.00 153 0 N.D.
24) 2,4-Dinitrotoluene 21.02 165 314 N.D.
25) Diethylphthalate 22.12 149 651 N.D.
26) 4-Chlorophenyl-phenylether 0.00 204 0 N.D.
27) Fluorene 0.00 166 0 N.D.
28) Azobenzen/ 1,2-Diphenylhyd 0.00 77 0 N.D.
(#) = qualifier out of range (m) = manual integration
29792.D GCMS1126.M Fri Dec 28 12:50:58 2001 Page 1
NYC-WTC_000037128
OCR can misread numbers and units. Confirm readings against the page image before using them.