NYC-WTC_000035233
Laboratory report showing non-detect levels for various volatile organic compounds in a WTC blank sample.
Same agency, volume and box · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗GCMS analysis results for sample AD28903 dated December 15, 2001, showing non-detect levels for various compounds.
NYC-WTC_000035563–000035570Folder label: “GCMS X 11/29/01 A 12/7/01”

OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Quantitation Report (QT Reviewed)
Data File C:\HPCHEM\1\DATA\DEC0 7 01\LB.D Vial: 7 Acq On 7 Dec 2001 8:47 pm Operator: 209 GALOS Sample 11/29 gc/ms scan Inst : GC/MS 209 Mise Multiplr: 1.00 MS Integration Params: RTEINT.P Quant Time: Dec 13 14:48 2001 Quant Results File: GCMS1126.RES Quant Method : C:\HPCHEM\1\METHODS\GCMS1126.M (RTE Integrator) Title : 209 625/TCLP calibration table Last Update : Thu Dec 13 14:40:46 2001 Response via : Initial Calibration DataAcq Meth : GCMS1126
Compound R.T. Qlon Response Cone Unit Qvalue 30) N-Nitrosodiphenylamine 0.00 168 0 N.D. 31) 4-Bromophenyl-phenylether .0.00 248 0 N.D. 32) Hexachlorobenzene 0.00 284 0 N.D. 3 3) Phenanthrene 24.98 178 961 N.D. 34) Anthracene 24.98 178 961 N.D. 35) Di-n-butylphthalate 26.99 149 8978 N.D. 36) Fluoranthene 0.00 202 0 N.D. 3 9) Pyrene 0.00 202 0 N.D. 40) Butylbenzylphthalate 31.49 149 2821 N.D. 41) Benzo(a)anthracene 33.01 228 4494 N.D. 42) Bis(2-ethylhexyl)phthalate 33.29 149 40712 0.41 ug/1 98 43) Chrysene 33.01 228 4494 N.D. 45) Di-n-Octylphthalate 35.04 149 627 N.D. 46) Benzo(b)fluoranthene 36.08 252 345 N.D. 47) Benzo(k)fluoranthene 36.13 252 586 N.D. 4 8) Benzo(a)pyrene 37.10 252 4856 N.D. 49) Indeno(l,2,3-cd)pyrene 0.00 276 0 N.D. 50) Dibenz(a,h)anthracene 0.00 278 0 N.D. 51) Benzo(g,h,i)perylene 0.00 276 0 N.D.
(#) = qualifier out of range (m) = manual integration LB.D GCMS1126.M Thu Dec 13 14:48:59 2001 Page 2
NYC-WTC_000035565
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000035233
Laboratory report showing non-detect levels for various volatile organic compounds in a WTC blank sample.
Same agency, volume and box · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035843
Lab notes for sample AD29190 indicate detection of di-n-butylphthalate and one LCS compound outside acceptance range.
Same agency, volume and box · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035990
Laboratory report noting detection of bis(2-Ethylhexyl)phthalate in sample AD29028 analyzed on December 18, 2001.
1 shared topics · Same agency, volume and box · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000034258
Laboratory report documenting GCMS analysis of sample AD28473 conducted between November 21 and 26, 2001.
Same agency, volume and box · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000034877
Laboratory analyst notes on GCMS scan results and recovery rates for sample AD28477 analyzed in early December 2001.
1 shared topics · Same agency, volume and box · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000016681
Method blank report confirming absence of contamination during volatile organic compound testing procedures in January 2002.
Similar document embedding; no shared entity or topic indexed. · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000016078
Laboratory blank report confirming no detectable contamination for nitrosamines and chlorinated solvents during the run.
1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000016285
Laboratory report of a GCMS blank run performed on February 7, 2002, to verify absence of contamination.
Similar document embedding; no shared entity or topic indexed. · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000016555
Blank analysis report for DEP sample AD31432 showing non-detect levels for volatile organic compounds from January 22, 2002.
1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000005159
Blank sample analysis report confirming no contamination above method detection limits for target compounds analyzed on February 1, 2002.
Similar document embedding; no shared entity or topic indexed. · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000016506
Blank analysis report for DEP sample AD31363 showing non-detect levels for volatile organic compounds from February 7, 2002.
Similar document embedding; no shared entity or topic indexed. · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000050079
Blank analysis report for GCMS testing of sample AE00005 showing non-detectable levels of target compounds.
1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000035865
Lab notes for sample AD29134 indicate detection of di-n-butylphthalate and one LCS compound outside acceptance range.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035598
Lab report noting no unusual compounds but recovery issues and low pH in a water sample.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035831
Lab notes for sample AD29141 indicate detection of bis(2-Ethylhexyl)phthalate and one LCS compound outside acceptance range.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000036232
Laboratory analysis report for sample AD29291 conducted on December 28, 2001, including surrogate recovery data.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035843
Lab notes for sample AD29190 indicate detection of di-n-butylphthalate and one LCS compound outside acceptance range.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035776
Laboratory data sheet recording GCMS analysis of a blank sample for nitrosamines and chlorinated compounds.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000035561
Department of Environmental Protection record logging GCMS X samples from November to December 2001.
Filed in the same folder
NYC-WTC_000035562
Fragmented document header containing metadata for gas chromatography-mass spectrometry analysis.
Filed in the same folder
NYC-WTC_000035571
GCMS method blank analysis for sample AD28903 dated December 7, 2001, showing non-detect levels.
Filed in the same folder
NYC-WTC_000035575
GCMS reference standard analysis for sample AD28903 dated December 7, 2001, showing measured concentrations.
Filed in the same folder
NYC-WTC_000035580
GCMS scan results for sample AD28903 dated December 15, 2001, detecting bis(2-Ethylhexyl)phthalate.
Filed in the same folder