NYC-WTC_000034971
Blank test results confirming no detectable contaminants above method detection limits for sample AD28662.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗Laboratory report noting low pH and TurboVap contamination with recovery data for sample AD28689.
NYC-WTC_000035195–000035228Folder label: “GCMS X 11/24/01 A 12/4/01”

OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document Library Search Compound Report
Data File : C:\HPCHEM\1\DATA\NOV2601\28682.D Vial: 10 Acq On : 28 Nov 2001 2:05 am Operator: 209 GALOS Sample : 11/24 scan Inst : GC/MS 209 Mise Multiplr: 1.00 MS Integration Params: LSCINT.P
Quant Method : C:\HPCHEM\1\METHODS\GCMS1126.M (RTE Integrator) Title : 209 625/TCLP calibration table Library : C:\DATABASE\NBS75K.L *************** * ** * * * * *** * * * ***************************************** Peak Number 3 3,6-Dioxa-2,4,5,7-tetrasilaoct Concentration Rank 1
R.T. EstConc Area Relative to ISTD R.T.
36.15 1.95 ug/1 179777 Perylene-dl2 37.12
Hit# of 5 Tentative ID MW MolForm CAS# Qual
1 3,6-Dioxa-2<4,5,7-tetrasilaoctane, 294 C10H3002Si4 004342-25-0 33 2 Trisiloxane, 1,1,1,5,5,5-hexamethyl 384 C12H36O4Si5 003555-47-3 27 3 1,2-Benzenedi carboxylic acid, bis(t 310 C14H22O4Si2 002078-22-0 14 4 Trisiloxane, octamethyl- 236C8H24O2Si3 000107-51-7 12 Abundance Scan 3389 (36.153 min): 28682.D (-) m/ z 73.00 100.00% 73 147 221
5000 281 355 35.80 36.00 36.20 36.40
miz-> 49 91 —T TT,TTTTTTT 193 . npmmmmm 253 253 1.. 227.41 ........ 1, 40 60 80 100120140 160 1 80200220240260280300320340 360380 400420 m/z 147.00 88.73% Abundance #41682: 3,6-Dioxa-2,4,5,7-tetrasilaoctane, 2,2,4,4,5,57,7- 147 221
73 5000- 35.80 36.00 36.20 36.40 191 117 279 m/z 220.90 / 79.60% __ ____________ | I T’’I"TIOUTETTCTTETITTTTTT mptpmmmmmm miz- 40 60 80 100120140160180200220240260280300 320 340360380400420 Abundance #74103; 7 siloxane, 1.1,1.5,5,5-hexamethyl-3,3-bis[uimet 73 147 "I 1 I ' 1 1 ' I I • ' ‘ I ' 1 ' ' I ' 35.80 36.00 36.20 36.40 5000 m/z 281.00 39.37? 39.37% 281 45 369 117 , 207 249 TTpT ’ITTTUTTCTTCICTTETTTTTTTUTTTTTTTTUTTTUTTTTTTTTTWTgTp m/z-> 40 60 80 100120140160180200220240260280300320 340360380400420 _ Vanoa Abundance #72972:1 2-Benzenedicarboxylic acid, bis(trimethylsilyl) e ■ I ■ ■ > ■ j > T TT 147 __ 35.80 36.00 36.20 36.40 m/z 207.00 34.56% 73 5000-
45 295 Pywwn miz-? l... ......... mfo -.... ........ 193 221 40 60 80 1001201401601802002202402602803003 20340360380400420 35.80 36.00 36.20 36.40
28682.D GCMS1126.M Mon Dec 10 12:12:18 2001 Page 3
NYC-WTC_000035227
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000034971
Blank test results confirming no detectable contaminants above method detection limits for sample AD28662.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035135
Laboratory report noting di-n-butylphthalate detection and low pH with recovery data for sample AD28694.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035072
Laboratory report noting TurboVap contamination and low recovery rate for sample AD28678.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035089
Laboratory report noting TurboVap contamination with recovery data for sample AD28693.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000034347
Laboratory report documenting GCMS analysis of sample AD28471 conducted on December 6, 2001.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035153
Laboratory report noting TurboVap contamination and recovery data for sample AD28663.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035115
Laboratory report noting TurboVap contamination and recovery data for sample AD28664.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035171
Laboratory report noting low recovery rate and TurboVap contamination for sample AD28677.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035008
Laboratory report detailing GCMS scan results for sample AD28669, noting phthalate detection and recovery rates.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035052
Laboratory report noting low pH and TurboVap contamination with recovery data for sample AD28691.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000034311
Laboratory report documenting GCMS analysis of sample AD28430 conducted on December 6, 2001.
1 shared topics · Same agency, volume and box · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000018546
Laboratory report showing GC/MS calibration data for polycyclic aromatic hydrocarbons and deuterated standards.
1 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000033765
Analytical commentary for sample AD28149 dated November 29, 2001, noting no unusual compounds but low recovery rates for LCS standards.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000034331
Laboratory report documenting GCMS analysis of sample AD28427 conducted between November 21 and 26, 2001.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000034799
Laboratory analyst notes on GCMS scan results and recovery rates for sample AD28593 analyzed in early December 2001.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000033752
Analytical commentary for sample AD28159 dated November 29, 2001, noting no unusual compounds but low recovery rates for LCS standards.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000033800
Analytical commentary for sample AD28157 dated November 29, 2001, noting no unusual compounds but low recovery rates for LCS standards.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000033789
Analytical commentary for sample AD28151 dated November 29, 2001, noting no unusual compounds but low recovery rates for LCS standards.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000034946
Laboratory report detailing GCMS scan results for sample AD28650, noting phthalate detection and low pH.
Filed in the same folder
NYC-WTC_000034947
Document containing unreadable text or corrupted data from the Department of Environmental Protection archives.
Filed in the same folder
NYC-WTC_000034949
Form detailing Method 508 parameters and sample volume information for environmental testing procedures.
Filed in the same folder
NYC-WTC_000034954
Reference data sheet listing concentrations of volatile organic compounds detected in sample AD28662.
Filed in the same folder
NYC-WTC_000034958
Calibration report showing recovery percentages for various chemical standards used in the GCMS analysis.
Filed in the same folder